Design strategies and performance of custom DNA sequencing primers.

نویسندگان

  • G A Buck
  • J W Fox
  • M Gunthorpe
  • K M Hager
  • C W Naeve
  • R T Pon
  • P S Adams
  • J Rush
چکیده

This study surveyed strategies of sequencing primer selection and evaluated primer performance in automated DNA sequencing. We asked participants to relate their preferred primer design strategies to identify primer characteristics that are considered most important in sequencing primer design. The participants preferred primers of 18-24 nucleotides (nt), 39%-58% G + C, a melting temperature (Tm) of 53 degrees-65 degrees C with a 1-2 nt 3' GC clamp, hairpin stems of less than 2-3 bp, homopolymeric runs of less than 4-5 nt, primer dimers of less than 3-4 bp and secondary priming sites of less than 3-4 bp. We provided a 300-bp test sequence and asked participants to submit sequences of 1-3 optimal sequencing primers. Submitted primers ranged from 17-24 nt and largely conformed to the preferred parameters. Submitted primers were distributed across the test sequence, although some sites were disfavored. Surprisingly, approximately 45% of the primers were selected "manually", more than by any software package. Each of 69 submitted and 95 control primers, distributed at 3-bp intervals across the test sequence, were synthesized, purified and tested using a Model 377 PRISM DNA Sequencer with dichlororhodamine dye terminator reagents (dRhodamine dye terminators). Approximately half of the control primers were also tested using rhodamine dye terminator reagents ("old" rhodamine dye terminators). The results indicated that primer physico-chemical characteristics thought to have a strong impact on sequencing performance had surprisingly little effect. Thus, primers with high or low percent G + C or Tm, strong secondary priming scores or long 3' homopolymeric stretches yielded excellent sequences with the dRhodamine dye terminator reagents, although these characteristics had a stronger effect when the old rhodamine reagents were used. The old rhodamine reagents gave sequences with a similar average read length, but the number of errors and ambiguities or "N's" was consistently higher. Moreover, the effects of the primer physico-chemical characteristics were also more evident with the old rhodamine dyes. We conclude that under optimal sequencing conditions with highly pure template and primer, many of the commonly applied primer design parameters are dispensable, particularly when using one of the new generation of sequencing reagents such as the dichlororhodamine dye terminators.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

MutScreener: primer design tool for PCR-direct sequencing

In searching for susceptibility genes, both positional cloning and candidate gene strategies have been helpful. Mutation screening is one of the many technologies that have been implemented in order to identify mutations or polymorphisms in candidate genes or genomic regions. Since human genome sequence is available, PCR-direct sequencing is one of the major methods for mutation screening or re...

متن کامل

Specific-primer-directed DNA sequencing using automated fluorescence detection.

Automated fluorescence-based DNA sequence analysis offers the possibility to undertake very large scale sequencing projects. Directed strategies, such as the specific-primer-directed sequencing approach ('gene walking'), should prove useful in such projects. Described herein is a study involving the use of this approach in conjunction with automated fluorescence detection on a commercial instru...

متن کامل

Position-dependent effects of locked nucleic acid (LNA) on DNA sequencing and PCR primers

Genomes are becoming heavily annotated with important features. Analysis of these features often employs oligonucleotides that hybridize at defined locations. When the defined location lies in a poor sequence context, traditional design strategies may fail. Locked Nucleic Acid (LNA) can enhance oligonucleotide affinity and specificity. Though LNA has been used in many applications, formal desig...

متن کامل

Strategies and Clinical Applications of Next Generation Sequencing

Abstract DNA sequencing is one of the great valuable techniques in molecular biology, which can be used to detect the sequence of nucleotides in a DNA fragment. The high-throughput se­quencing known as Next Generation Sequencing (NGS) revolutionized genomic research and molecular biology; therefore, the whole human genome can be sequenced with a low cost in several days. NGS technology is simi...

متن کامل

PCR Strategies for Complete Allele Calling in Multigene Families Using High-Throughput Sequencing Approaches

The characterization of multigene families with high copy number variation is often approached through PCR amplification with highly degenerate primers to account for all expected variants flanking the region of interest. Such an approach often introduces PCR biases that result in an unbalanced representation of targets in high-throughput sequencing libraries that eventually results in incomple...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • BioTechniques

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 1999