Image-based navigation improves the positioning of the humeral component in total elbow arthroplasty.

نویسندگان

  • Colin P McDonald
  • James A Johnson
  • Terry M Peters
  • Graham J W King
چکیده

HYPOTHESIS Implant alignment in total elbow arthroplasty (TEA) is a challenging and error-prone process using conventional techniques. Identification of the flexion-extension (FE) axis is further complicated for situations of bone loss. This study evaluated the accuracy of humeral component alignment in TEA. We hypothesized that an image-based navigation system would improve humeral component positioning, with navigational errors less than or approaching 2.0 mm and 2.0 degrees . MATERIALS AND METHODS Implantation of a modified commercial TEA humeral component was performed with and without navigation on 11 cadaveric distal humeri. Navigated alignment was based on positioning the humeral component with the aid of a computed tomography (CT)-based preoperative plan registered to landmarks on the distal humerus. Alignment was performed under 2 scenarios of bone quality: (1) an intact distal humerus, and (2) a distal humerus without articular landmarks. RESULTS Navigation significantly improved implant alignment accuracy (P < .001). Navigated implant alignment was 1.2 +/- 0.3 mm in translation and 1.3 degrees +/- 0.3 degrees in rotation for the intact scenario. For the bone loss scenario, navigated alignment error was 1.1 +/- 0.5 mm and 2.0 degrees +/- 1.3 degrees . Non-navigated alignment was 3.1 +/- 1.3 mm and 5.0 degrees +/- 3.8 degrees for the intact scenario and 3.0 +/- 1.6 mm and 12.2 degrees +/- 3.3 degrees for the bone loss scenario. DISCUSSION Image-based navigation improves the accuracy and reproducibility of humeral component placement in TEA. Implant alignment errors for the navigated alignments were below the target of 2.0 degrees and 2 mm that is considered standard for most navigation systems. Non-navigated implant alignment error was significantly greater for the bone loss scenario compared with the intact scenario. CONCLUSIONS Implant malalignment may increase the likelihood of early implant wear, instability, and loosening. Improved implant positioning will likely lead to fewer complications and greater prosthesis longevity.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Biomechanical consequences of humeral component malpositioning after anatomical total shoulder arthroplasty.

HYPOTHESIS We hypothesized that the malpositioning of the humeral component can preclude the long-term success of anatomical total shoulder arthroplasty. The goal of this study was to evaluate the mechanical consequences of superior and inferior malpositioning of the humeral head. MATERIALS AND METHODS A numerical musculoskeletal model of the shoulder joint allowing natural humeral head trans...

متن کامل

Current concepts in elbow arthroplasty

Distal humeral replacement and the total elbow are two commonly-used arthroplastiesEach prosthesis has evolving indications and surgical techniquesRecent changes in device design and implantation methods are due to biomechanical and clinical outcome-based researchNew prostheses and methods provide: better elbow kinematics, more durable bearings and longer-lasting joint replacement potential Cit...

متن کامل

Comparison of two types of ulnar component in type-5 Kudo total elbow arthroplasty in patients with rheumatoid arthritis: a long-term follow-up.

The purpose of this study was to assess the long-term results (more than ten years) of two types of cemented ulnar component with type-5 Kudo total elbow arthroplasty in a consecutive series of 56 patients (60 elbows) with rheumatoid arthritis, and to compare the results in elbows above and below a Larsen grade IV. There was no radiolucency around the humeral component. Patients in whom a metal...

متن کامل

Observations on retrieved humeral polyethylene components from reverse total shoulder arthroplasty.

HYPOTHESIS Analyses of polyethylene components retrieved at revision of total knee, hip, and shoulder replacements have been used to study the effect of design, patient, and surgical factors on initial implant performance, but no studies have reported similar types of findings in retrieved humeral polyethylene components in reverse total shoulder arthroplasty. Our hypothesis is that while the c...

متن کامل

GPS Jamming Detection in UAV Navigation Using Visual Odometry and HOD Trajectory Descriptor

Auto-navigating of unmanned aerial vehicles (UAV) in the outdoor environment is performed by using the Global positioning system (GPS) receiver. The power of the GPS signal on the earth surface is very low. This can affect the performance of GPS receivers in the environments contaminated with the other source of radio frequency interference (RFI). GPS jamming and spoofing are the most serious a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of shoulder and elbow surgery

دوره 19 4  شماره 

صفحات  -

تاریخ انتشار 2010