Gafchromic EBT‐XD film: Dosimetry characterization in high‐dose, volumetric‐modulated arc therapy

نویسندگان

  • Hideharu Miura
  • Shuichi Ozawa
  • Fumika Hosono
  • Naoki Sumida
  • Toshiya Okazue
  • Kiyoshi Yamada
  • Yasushi Nagata
چکیده

Radiochromic films are important tools for assessing complex dose distributions. Gafchromic EBT-XD films have been designed for optimal performance in the 40-4,000 cGy dose range. We investigated the dosimetric characteristics of these films, including their dose-response, postexposure density growth, and dependence on scanner orientation, beam energy, and dose rate with applications to high-dose volumetric-modulated arc therapy (VMAT) verification. A 10 MV beam from a TrueBeam STx linear accelerator was used to irradiate the films with doses in the 0-4,000 cGy range. Postexposure coloration was analyzed at postirradiation times ranging from several minutes to 48 h. The films were also irradiated with 6 MV (dose rate (DR): 600 MU/min), 6 MV flattening filter-free (FFF) (DR: 1,400 MU/ min), and 10 MV FFF (DR: 2,400 MU/min) beams to determine the energy and dose-rate dependence. For clinical examinations, we compared the dose distribu-tion measured with EBT-XD films and calculated by the planning system for four VMAT cases. The red channel of the EBT-XD film exhibited a wider dynamic range than the green and blue channels. Scanner orientation yielded a variation of ~ 3% in the net optical density (OD). The difference between the film front and back scan orientations was negligible, with variation of ~ 1.3% in the net OD. The net OD increased sharply within the first 6 hrs after irradiation and gradually afterwards. No significant difference was observed for the beam energy and dose rate, with a variation of ~ 1.5% in the net OD. The gamma passing rates (at 3%, 3 mm) between the film- measured and treatment planning system (TPS)-calculated dose distributions under a high dose VMAT plan in the absolute dose mode were more than 98.9%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Dosimetry of gamma chamber blood irradiator using Gafchromic EBT film.

Gafchromic films are increasingly being used for dosimetry in medical and industrial applications of ionizing radiation because of their favorable characteristics such as self developing in nature, easy to handle, dose rate independent response, insensitivity to normal room lights, high resolution and insensitivity to variation in the environment conditions. The dosimetry measurements using Gaf...

متن کامل

Evaluation of triple channel correction acquisition method for radiochromic film dosimetry

The purpose of this study was to evaluate the triple channel correction acquisition (TCCA) method for radiochromic film dosimetry performed with a flatbed scanner. The study had two parts: a fundamental and a clinical examination. In the fundamental examination, we evaluated the accuracy of calibration curves for Gafchromic EBT2 (EBT2). The films were calibrated using a field-by-field method wi...

متن کامل

Performance of the Vidar Dosimetry Pro Advantage

The Vidar use with r designed t work in th compared reported f resolution scattering artifact of eliminated the Red L the availa scanner y linear acc INTERNATIONAL SPECIALTY PRODUCTS 1361 Alps Road Wayne NJ 07470∙ Tel: 973-628-4000 rmance of the Vidar Red LED Dosimetry Pro AdvantageTM: r optimized for use with GAFCHROMIC EBT Dosimetry Film. avid F. Lewis, Ph.D., Senior Director, Advanced Materi...

متن کامل

Optimizing the dynamic range extension of a radiochromic film dosimetry system.

The authors present a radiochromic film dosimetry protocol for a multicolor channel radiochromic film dosimetry system consisting of the external beam therapy (EBT) model GAFCHROMIC film and the Epson Expression 1680 flat-bed document scanner. Instead of extracting only the red color channel, the authors are using all three color channels in the absorption spectrum of the EBT film to extend the...

متن کامل

Three-dimensional radiochromic film dosimetry for volumetric modulated arc therapy using a spiral water phantom

We validated 3D radiochromic film dosimetry for volumetric modulated arc therapy (VMAT) using a newly developed spiral water phantom. The phantom consists of a main body and an insert box, each of which has an acrylic wall thickness of 3 mm and is filled with water. The insert box includes a spiral film box used for dose-distribution measurement, and a film holder for positioning a radiochromic...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 17  شماره 

صفحات  -

تاریخ انتشار 2016