Implantable Microcoil for In-vivo Magnetic Resonance Spectroscopy
ثبت نشده
چکیده
The Nuclear Magnetic Resonance Spectroscopy (MRS) is the study metabolic processes in different biological and chemical samples as tissues, cell cultures, and protein structures. MRS fulfils an important role through its ability to deduce structural information and to withdraw microscopic data from the intermolecular dynamics. The NMR Approach has expand its capacities to cover furthermost medical and chemical diagnosis applications. However, NMR sensitivity still lags significantly behind most other analytical techniques by a factor of 100-1000, mainly for mass-limited and concentration-limited samples [1]. The observation of metabolic processes using short spin-spin relaxation decay becomes possible via short echo-time localization pulse-sequences. Yet, spectra quantification is obstructed by overlapping metabolite resonances and by low Signal-to-Noise Ratio (SNR) due to the limited size of the observed volume. Hence, the analysis of sample volumes of nanoliter order point toward the improvement of Radio-Frequency (RF) coils having dimensions of several micrometers [2,3]. The sensitivity of an NMR receiver coil is expressed as a ratio of the SNR and the concentration of the measured substance [4]:
منابع مشابه
Designing and Fabrication of a New Radiofrequency Planar microcoil for mini-Nuclear Magnetic Resonance
Introduction Radiofrequency planar microcoils are used to increase the resolution of magnetic resonance images of small samples. In this study, we aimed to design and fabricate a spiral planar microcoil constructed on a double-sided printed circuit board (PCB). It has four rings with an internal diameter of 241 microns tuned and matched at 63.8 MHz. Materials and Methods To achieve the maximum ...
متن کاملIn vivo 31P magnetic resonance spectroscopy using a needle microcoil.
Batch fabrication methods have been used to produce low-cost microcoils for magnetic resonance spectroscopy (MRS) that could be discarded after applications such as insertion into tissue during interventional surgery. Needle-shaped microcoils were constructed using electroplated conductors buried in shafts formed with different combinations of silicon and plastic and used to acquire in vivo (31...
متن کاملIntraductal micro magnetic resonance imaging and spectroscopy
The majority of breast cancers originate in the mammary ducts. As such many diagnostic techniques introduce mmdiameter devices into the ducts through the nipple. Established intraductal techniques include ductal lavage, and white-light or fluorescence endoscopy. While reported values vary, these techniques typically suffer from low sensitivity and specificity. Similarly, Magnetic Resonance Imag...
متن کاملMicrocoil high-resolution magic angle spinning NMR spectroscopy.
We report the construction of a dual-channel microcoil nuclear magnetic resonance probehead allowing magic-angle spinning for mass-limited samples. With coils down to 235 mum inner diameter, this allows high-resolution solid-state NMR spectra to be obtained for amounts of materials of a few nanoliters. This is demonstrated by the carbon-13 spectrum of a tripeptide and a single silk rod, prepare...
متن کاملMicrofluidically Cryo-cooled Inductively Coupled Spiral Microcoils for Mr Microscopy
The development of a microfluidically cryo-cooled and inductively coupled spiral microcoil for magnetic resonance (MR) microscopy with high signal-to-noise ratio (SNR) is presented. The microcoil was inductively coupled to a secondary coil that was directly coupled to a transmission line. This configuration eliminated thermal flux through direct connection when the microcoil was cryo-cooled to ...
متن کامل