Technical Note: A new device for cervical insemination of sheep - design and field test.

نویسندگان

  • A Macías
  • L M Ferrer
  • J J Ramos
  • I Lidón
  • R Rebollar
  • D Lacasta
  • M T Tejedor
چکیده

Deep semen deposition, avoiding retrograde flow, lesions and stress, has proved to be very important in the success of sheep AI. The objective of the present study was to develop a new, suitable anti-retrograde flow device for sheep cervical AI (DARIO) that enables deep deposition of semen into the cervix without any modifications to the procedures currently used, and to compare the fertility, fecundity, and prolificacy rates between DARIO and a traditional catheter. Field tests were performed on 16 farms actively participating in the non-profit National Association of Rasa Aragonesa Breeders´ genetic selection scheme and where sheep management was similar. A total of 242 AI lots were considered, including 1,299 ewes; 126 lots (662 ewes) were inseminated using DARIO, and 116 lots (637 ewes) using a traditional commercially-available catheter (control group). Several factors affecting AI results were included in the model for mean comparison between DARIO and control groups (farm and ram as random factors; catheter, year and photoperiod as fixed effects; catheter × photoperiod interaction). The type of catheter had a significant effect on fertility ( < 0.01) and fecundity rates ( < 0.01) but no significant effect was detected on the prolificacy rate ( = 0.45). For fertility rate (percentage of ewes lambing after AI), means ± SE for DARIO and control groups were 59.44 ± 2.13% and 49.60 ± 2.48%, respectively; for fecundity rates, means ± SE for DARIO and control groups were 0.99 ± 0.04 and 0.82 ± 0.05 lambs/inseminated ewe, respectively, and, for prolificacy rates, means ± SE for DARIO and control groups were 1.68 ± 0.04 and 1.63 ± 0.04 lambs/ewe lambing, respectively. Fertility rate was greater in the decreasing photoperiod ( = 0.01). Significant effects were found for both year ( < 0.05) and farm ( < 0.01) on fertility, fecundity, and prolificacy rates. Neither ram nor catheter × photoperiod showed any significant effects on the variables investigated ( > 0.05). Overall, the use of DARIO instead of the traditional commercially-available catheter increased both fertility and fecundity rates; the marginal mean differences were 9.05 pregnant ewes per 100 inseminated and 0.15 lambs per inseminated ewe, respectively.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Effects of Using Artificial Insemination Techniques on Reproductive Performance in Ghezel Sheep

Objective: The aim of the present study was to evaluate artificial insemination techniques on reproductive performance in Ghezel ewes synchronized with CIDR during breeding season. Methods: All ewes were treated with controlled internal drug release device (CIDR) inserted into the vagina of the ewes for 14 days. All ewes were treated a single intramuscular (IM) dose of PMSG was injected. In thi...

متن کامل

The Effects of Using Artificial Insemination Techniques on Reproductive Performance in Ghezel Sheep

Objective: The aim of the present study was to evaluate artificial insemination techniques on reproductive performance in Ghezel ewes synchronized with CIDR during breeding season. Methods: All ewes were treated with controlled internal drug release device (CIDR) inserted into the vagina of the ewes for 14 days. All ewes were treated a single intramuscular (IM) dose of PMSG was injected. In thi...

متن کامل

A New Stethoscope Design with Unique Characteristics and Development in Medical Device

As regards the significant role of stethoscopes in the diagnosis of congenital and adventitious heart diseases and prevention of irreparable complications of these diseases, the quality of hearing sound of these stethoscopes by a physician has a significant impact on the disease diagnosis. This device plays an important role in the early diagnosis of congenital heart and respiratory diseases an...

متن کامل

Research Paper: Evaluating Gross Anatomy of Cervix in Zel Sheep

Introduction: Many previous studies have proved that the anatomical features of cervix can affect the success of artificial insemination. These characteristics differ in sheep breeds. This study aimed to describe the anatomical features of cervix in Zell ewes; the only tailed sheep in Iran. Methods: Eighty nonpregnant and clinically healthy reproductive tracts of adult Zel sheep were collected...

متن کامل

Twin Plate Weir: A Flow Measuring Device (TECHNICAL NOTE)

For efficient use of water, accurate measurement of flow in (field/laboratory) channels is required for many water resource projects. The present work is aimed to study the flow characteristics of a twin plate weir (two sharp-crested plates are placed one behind the other at some distance) under free and submerged flow conditions. Experiments are performed with four spacing of the twin plate we...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of animal science

دوره 95 12  شماره 

صفحات  -

تاریخ انتشار 2017