A useful monochromator drive system for spectral scanning.
نویسنده
چکیده
HALLDAL[l] describes the use of an interference-wedge filter as a simple monochromator for recording different types of spectra. His use of the cam and screen to obtain equal quanta is particularly clever. We have used interference-wedge filters in a similar way for the purpose of recording fluorescence emission spectra[2,3]. I t is frequently useful and efficient to be able to change the scanning speed of a monochromator during a run so that it is slow in spectral regions where the property being measured changes rapidly with wavelength and conversely. However, to achieve satisfactory results, the recording speed must be changed simultaneously with the monochromator scan speed. This can be done easily in Halldal’s instrument (or with any other monochromator) with a relatively simple modification [3]. The modification consists of using a stepping motor and multispeed chart drive unit (Heath # EU-20-26) for a Heath servo chart recorder in place of the multispeed synchronous motor (# 5 in Halldal’s Fig. I ) to drive the interference wedge or monochromator and recording on a Heath recorder equipped with the multispeed attachment. The stepping motor used to drive the wedge can be either unidirectional (A. W. Haydon series 45 100) or bidirectional (Haydon series 44100), although the motor drive unit may need some slight modifications to accommodate the bidirectional motor. The wedge motor drive unit is then driven by the output signal from the recorder chart drive unit, rather than its own internal 60 cycle signal (or conversely, depending on which motor requires the higher frequency of stepping pulses). This results in a constant speed ratio between the two motors. The actual ratio is determined by the speed setting on the slave unit. The absolute scan speed of both together can then be vaned, while maintaining the constant ratio between them, by varying the speed setting of the master drive unit. Using a more complex programming between the wedge and recorder drive units, it may be possible to correct for the nonlinearity of wavelength with distance along the wedge which occurs in these interference wedges; we have not attempted to do this. I t should also be noted that when studying physiological processes which require corrections for instrumental or physiological drifts in time, such as the action spectra described by Halldal[l], it may be necessary to keep the scanning rate constant over the entire range of measurement to be able to make the corrections.
منابع مشابه
The calibration of scanning monochromators for the measurement of absolute irradiance.
Certain approximations commonly used in the absolute calibration of a scanning monochromator are examined in terms of the response of the instrument to a monochromatic input. The absolute irradiance due to any spectral feature in the neighborhood of lambda(0) is commonly computed from the expression W = AB(lambda(0))/H(lambda(0)) where A is the area of the spectral feature as recorded by the mo...
متن کاملDYNAMICAL ANALYSIS AND DESIGN OF FRONT ENGINE ACCESSORY DRIVE SYSTEM
In this paper, Front Engine Accessory Drive (FEAD) system of automotive engine is modeled with ADAMS software. The model is validated using engine test data. It is then used to investigate the effect of design parameters on the system performance such as belt vibration and loads on the idlers. Three alternative layouts were developed in order to improve the performance of original EEAD system. ...
متن کاملHigh-energy-resolution monochromator for aberration-corrected scanning transmission electron microscopy/electron energy-loss spectroscopy.
An all-magnetic monochromator/spectrometer system for sub-30 meV energy-resolution electron energy-loss spectroscopy in the scanning transmission electron microscope is described. It will link the energy being selected by the monochromator to the energy being analysed by the spectrometer, without resorting to decelerating the electron beam. This will allow it to attain spectral energy stability...
متن کاملOptimized Spectrometers Characterization Procedure for Near Ground Support of ESA FLEX Observations: Part 1 Spectral Calibration and Characterisation
The paper presents two procedures for the wavelength calibration, in the oxygen telluric absorption spectral bands (O2-A, λc = 687 nm and O2-B, λc = 760.6 nm), of field fixed-point spectrometers used for reflectance and Sun-induced fluorescence measurements. In the first case, Ne and Ar pen-type spectral lamps were employed, while the second approach is based on a double monochromator setup. Th...
متن کاملStretchable diffraction gratings for spectrometry.
We have investigated the possibility of using transparent stretchable diffraction gratings for spectrometric applications. The gratings were fabricated by replication of a triangular-groove master into a transparent viscoelastic. The sample length, and hence the spatial period, can be reversibly changed by mechanical stretching. When used in a monochromator with two slits, the stretchable grati...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Photochemistry and photobiology
دوره 11 4 شماره
صفحات -
تاریخ انتشار 1970