Design and analysis of orthogonally compliant features for local contact pressure relief in transtibial prostheses.
نویسندگان
چکیده
A very attractive advantage of manufacturing prosthetic sockets using solid freeform fabrication is the freedom to introduce design solutions that would be difficult to implement using traditional manufacturing techniques. Such is the case with compliant features embedded in amputee prosthetic sockets to relieve contact pressure at the residual limb-socket interface. The purpose of this study was to present a framework for designing compliant features to be incorporated into transtibial sockets and manufacturing prototypes using selective laser sintering (SLS) and Duraform material. The design process included identifying optimal compliant features using topology optimization algorithms and integrating these features within the geometry of the socket model. Using this process, a compliant feature consisting of spiral beams and a supporting external structure was identified. To assess its effectiveness in reducing residual limb-socket interface pressure, a case study was conducted using SLS manufactured prototypes to quantify the difference in interface pressure while a patient walked at his self-selected pace with one noncompliant and two different compliant sockets. The pressure measurements were performed using thin pressure transducers located at the distal tibia and fibula head. The measurements revealed that the socket with the greatest compliance reduced the average and peak pressure by 22% and 45% at the anterior side distal tibia, respectively, and 19% and 23% at the lateral side of the fibula head, respectively. These results indicate that the integration of compliant features within the socket structure is an effective way to reduce potentially harmful contact pressure and increase patient comfort.
منابع مشابه
The quasi-static response of compliant prosthetic sockets for transtibial amputees using finite element methods.
The finite element method (FEM) is a very powerful tool for analyzing the behavior of structures, especially when the geometry and mechanics are too complex to be modeled with analytical methods. This study focuses on the analysis of patellar tendon bearing prosthetic sockets with integrated compliant features designed to relieve contact pressure between the residual limb and socket. We develop...
متن کاملA Variable-Impedance Prosthetic Socket for a Transtibial Amputee Designed from Magnetic Resonance Imaging Data
This article evaluates the design of a variable impedance prosthetic (VIPr) socket for a transtibial amputee using computeraided design andmanufacturing (CAD/CAM) processes. Compliant features are seamlessly integrated into a three-dimensional printed socket to achieve lower interface peak pressures over bony protuberances by using biomechanical data acquired through surface scanning and magnet...
متن کاملValidity of method to quantify transtibial amputees' free-living prosthetic wearing times and physical activity levels when using suction suspension sockets.
Prostheses are prescribed to restore the mobility of people with amputated lower limbs. Monitoring the prosthesis wearing times and physical activity of prosthesis users would provide invaluable information regarding rehabilitation progress and suitability of the prosthesis. The validation of a method to determine wearing times and physical activity state, as well as strides taken, of amputees ...
متن کاملStatic Bending Analysis of Foam Filled Orthogonally Rib-Stiffened Sandwich Panels: A Mathematical Model
The current study presents a mathematical modeling for sandwich panels with foam filled orthogonally rib-stiffened core using Heaviside distribution functions. The governing equations of the static problem have been derived based on classical lamination theory. The present model contains three displacement variables considering all of the stiffness coefficients. A closed form solution using Gal...
متن کاملThe effect of toe only rocker shoe 10 and 15 degree compared to control shoe on plantar pressure, force and surface in healthy older adult
Objective: The aim of present study was to investigate the effect of toe only rocker with an angle of 10 and 15 degrees on the distribution of plantar pressure in healthy elderly people. The purpose of this study was to evaluate the plantar pressure of the foot and to remove excessive pressure from different parts of the plantar surface of the foot in order to maintain the independence and func...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of biomechanical engineering
دوره 127 6 شماره
صفحات -
تاریخ انتشار 2005