Simultaneous laboratory-based comparison of ResMed Autoset with polysomnography in the diagnosis of sleep apnoea/hypopnoea syndrome.
نویسندگان
چکیده
ResMed Autoset (AS) is a simplified diagnosis system for obstructive sleep apnoea/hypopnoea syndrome (OSAS) based on the respiratory flow/time relationship by pressure variation measured through simple nasal prongs. A multicentre prospective trial was used to compare AS and polysomnography (PSG) for diagnosing 95 patients, with suspected OSAS. Physicians gave a pretest probability of the patient having OSAS. The apnoea/hypopnoea index (AHI) was compared between the two methods of diagnosis for the whole population and for subgroups according to the pretest probability. Twenty-four patients had AHI < 15 events x h(-1) on PSG and 19 AHI 15-30, and 52 patients had AHI > or = 30. Correlation between AHI assessed by AS and PSG was r=0.87 for total sleep time (TST), p<0.0001. A Bland and Altman plot gave an agreement between the two methods of +/-40%. For a threshold of AHI > or = 15 events x h(-1) to diagnose OSAS, AS has a sensitivity of 92%, specificity of 79%, positive predictive value of 93% and negative predictive value of 76%. With a pretest probability > or = 80%, sensitivity and positive predictive value were 98 and 100% respectively. Of six false negative, four had a high pretest probability (> 80%) or Epworth score > or = 10. Using these parameters as a criterion for proceeding to PSG after a negative AS study would mean that two apnoeic patients (AHI 20 and 17 events x h(-1) by PSG) would escape detection. The Autoset is useful for the detection of obstructive sleep apnoea but with high pretest probability and a negative Autoset result polysomnography should be performed.
منابع مشابه
Comparison of ResMed AutoSet (version 3.03) with polysomnography in the diagnosis of the sleep apnoea/hypopnoea syndrome.
In patients with the sleep apnoea/hypopnoea syndrome (SAHS), accurate and timely diagnostic evaluation and initiation of effective treatment is important. Therefore, an increasing number of limited sleep studies are now performed nowadays diagnosing the SAHS in typical patients. It was the aim of the present study to evaluate the diagnostic accuracy of one such system, the updated ResMed Sulliv...
متن کاملComparison of polysomnography with ResCare Autoset in the diagnosis of the sleep apnoea/hypopnoea syndrome.
BACKGROUND Increasing referral numbers make the development of simplified accurate methods of diagnosing the sleep apnoea/hypopnoea syndrome highly desirable. The accuracy of one such system--the ResCare Autoset--has been examined. METHODS Thirty one consecutive patients assessed by polysomnography had simultaneous monitoring of their respiratory pattern using the Autoset system. The Autoset ...
متن کاملComparison of a limited computerized diagnostic system (ResCare Autoset) with polysomnography in the diagnosis of obstructive sleep apnoea syndrome.
The increasing numbers of patients referred for evaluation of suspected obstructive sleep apnoea (OSA) places a growing burden on available sleep laboratory resources. A number of limited diagnostic systems have been developed in an effort to cope with this clinical problem. In this study, the diagnostic capabilities of one limited diagnostic system (ResCare Autoset) were compared with full pol...
متن کاملAccuracy of an intelligent CPAP machine with in-built diagnostic abilities in detecting apnoeas: a comparison with polysomnography.
BACKGROUND In patients with sleep apnoea early diagnostic evaluation and treatment may be delayed due to limited access to full polysomnography (PSG). For "typical" patients, simplified strategies are needed. A study was performed to evaluate the accuracy of a new continuous positive airway pressure (CPAP) device with in-built diagnostic abilities (Autoset) in detecting apnoeas. METHODS Twent...
متن کاملDetection of apnoeas, hypopnoeas and arousals by the AutoSet in the sleep apnoea/hypopnoea syndrome.
Limited sleep study systems are increasingly being used to diagnose the sleep apnoea/hypopnoea syndrome, but validation is essential and detection of arousal's desirable. One such system (AutoSet) was validated on an event-by-event basis, and the hypothesis that sudden large breaths detected by this system mark arousal from sleep was also examined. Twenty consecutive patients (apnoea/hypopnoea ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- The European respiratory journal
دوره 12 4 شماره
صفحات -
تاریخ انتشار 1998