Effect of tidal volume on the output and particle size distribution of hypertonic saline from an ultrasonic nebulizer.

نویسندگان

  • J Riedler
  • C F Robertson
چکیده

The purpose of the present study was to measure the output and particle size distribution of hypertonic saline from an ultrasonic nebulizer over the range of tidal volumes (VT) used in an epidemiological survey of asthma in children. A Starling pump was used to generate different VTs from 250 to 500 ml, at different respiratory rates of 12 and 20 breaths.min-1, to cover the normal range of respiratory pattern of children aged 7-14 yrs. The Starling pump was connected to a Timeter Compuneb Ultrasonic Nebulizer Model MP 500 with 24 cm of corrugated aerosol tubing, ID 2.2 cm, and a two-way non-rebreathing valve. Nebulizer output was measured by weighing the nebulizer chamber plus tubing and valve before and after each nebulization. To measure particle size distribution, a Malvern Particle Sizer M 3.0 (laser diffraction) was used, with a special adapter attached between valve and Starling pump. Nebulizer output increased linearly from 1.6 to 2.5 ml.min-1 for VT 250 to 500 ml, with little influence by the respiratory frequency. Furthermore, we found that in the range of VT = 300-500 ml the mass median aerodynamic diameter (MMAD) was 2.61 microns, with 100% of the particles less than 5 microns, whereas at VT = 150-250 ml the MMAD was 8.89 microns, with 90% larger than 5 microns. As output from this ultrasonic nebulizer correlates linearly with tidal volumes, size correction may not be necessary in hypertonic saline challenge tests in children. Above a VT of 300 ml, the MMAD is in the respirable range, with 100% of particles less than 5 microns.(ABSTRACT TRUNCATED AT 250 WORDS)

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Therapeutic effects of Ventolin versus hypertonic saline 3% for acute bronchiolitis in children

  Background: Complications of Ventolin as the most common drug used for bronchiolitis are widely known. The present study was conducted to determine the efficacy of hypertonic saline 3%, compared with Ventolin, for treatment of acute bronchiolitis in children.   Methods : This double-blinded clinical trial study was conducted in Hajar Hospital, Shahrekord, Iran, from 2011 to 2012. A total of 7...

متن کامل

An in vitro analysis of the output of salbutamol from different nebulizers.

The objective of this study was to determine the particle size and mass output of salbutamol from different nebulizers used under simulated breathing conditions. Seven nebulizer/compressor combinations were assessed. Each nebulizer was charged with 5 mg salbutamol solution and connected to a breathing simulator operating at tidal volumes of 150 mL and 600 mL. Nebulizers were operated for 15 min...

متن کامل

COMPARISON BETWEEN THE EFFECTS OF 5 PERCENT HYPERTONIC SODIUM CHLORIDE SOLUTION AND 0.9 PERCENT SODIUM CHLORIDE SOLUTION ON LEFT VENTRICUL AR CONTRACTION

Hypertonic saline solution can absorb part of the intracellular fluid volume into the extracellular space. The effects of this solution on the cardiovascular system are increased coronary flow and increased left ventricular contraction, without sympathetic system activation. This study was designed to assess the effects of hypertonic saline solution in open heart surgery and to compare it w...

متن کامل

Some technical factors influencing the induction of sputum for cell analysis.

Inhalation of hypertonic saline aerosol is a relatively noninvasive method to obtain sputum for examination of inflammatory processes in the airways. We investigated some technical factors which might influence the success of induction and sputum cell counts. In total, twenty six asthmatic and 13 healthy subjects, unable to raise sputum spontaneously, inhaled nebulized saline for three 7 min in...

متن کامل

Physicochemical aspects and efficiency of albuterol nebulization: comparison of three aerosol types in an in vitro pediatric model.

BACKGROUND Advances in nebulizer design have produced both ultrasonic nebulizers and devices based on a vibrating mesh (vibrating mesh nebulizers), which are expected to enhance the efficiency of aerosol drug therapy. The aim of this study was to compare 4 different nebulizers, of 3 different types, in an in vitro model using albuterol delivery and physical characteristics as benchmarks. METH...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European respiratory journal

دوره 7 5  شماره 

صفحات  -

تاریخ انتشار 1994