Linear regression model for predicting patient-specific total skeletal spongiosa volume for use in molecular radiotherapy dosimetry.

نویسندگان

  • James M Brindle
  • A Alexandre Trindade
  • Amish P Shah
  • Derek W Jokisch
  • Phillip W Patton
  • J Carlos Pichardo
  • Wesley E Bolch
چکیده

UNLABELLED The toxicity of red bone marrow is widely considered to be a key factor in restricting the activity administered in molecular radiotherapy to suboptimal levels. The assessment of marrow toxicity requires an assessment of the dose absorbed by red bone marrow which, in many cases, requires knowledge of the total red bone marrow mass in a given patient. Previous studies demonstrated, however, that a close surrogate-spongiosa volume (combined tissues of trabecular bone and marrow)-can be used to accurately scale reference patient red marrow dose estimates and that these dose estimates are predictive of marrow toxicity. Consequently, a predictive model of the total skeletal spongiosa volume (TSSV) would be a clinically useful tool for improving patient specificity in skeletal dosimetry. METHODS In this study, 10 male and 10 female cadavers were subjected to whole-body CT scans. Manual image segmentation was used to estimate the TSSV in all 13 active marrow-containing skeletal sites within the adult skeleton. The age, total body height, and 14 CT-based skeletal measurements were obtained for each cadaver. Multiple regression was used with the dependent variables to develop a model to predict the TSSV. RESULTS Os coxae height and width were the 2 skeletal measurements that proved to be the most important parameters for prediction of the TSSV. The multiple R(2) value for the statistical model with these 2 parameters was 0.87. The analysis revealed that these 2 parameters predicted the estimated the TSSV to within approximately +/-10% for 15 of the 20 cadavers and to within approximately +/-20% for all 20 cadavers in this study. CONCLUSION Although the utility of spongiosa volume in estimating patient-specific active marrow mass has been shown, estimation of the TSSV in active marrow-containing skeletal sites via patient-specific image segmentation is not a simple endeavor. However, the alternate approach demonstrated in this study is fairly simple to implement in a clinical setting, as the 2 input measurements (os coxae height and width) can be made with either pelvic CT scanning or skeletal radiography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Method for estimating skeletal spongiosa volume and active marrow mass in the adult male and adult female.

UNLABELLED Active bone marrow is one of the more radiosensitive tissues in the human body and, hence, it is important to predict and possibly avoid myelotoxicity in radionuclide therapies. The MIRD schema currently used to calculate marrow dose generally requires knowledge of the patient's total skeletal active marrow mass -- a value that, at present, cannot be directly measured. Conceptually, ...

متن کامل

Investigation of effect of variations in bone fraction and red marrow cellularity on bone marrow dosimetry in radio-immunotherapy.

A method is described for computing patient-specific absorbed dose rates to active marrow which accounts for spatial variation in bone volume fraction and marrow cellularity. A module has been added to the 3D Monte Carlo dosimetry program DPM to treat energy deposition in the components of bone spongiosa distinctly. Homogeneous voxels in regions containing bone spongiosa (as defined on CT image...

متن کامل

Skin in vivo Dosimetry in Radiotherapy

Introduction: Due to the prevalence of skin problems in patients after radiotherapy, skin dose measuring is importance. Content: Skin in vivo dosimetry means measuring the patient's (or phantom) skin dose during radiotherapy. According to the ICRP 59, the dose at the depth of 0.07 mm is known as a skin dose. The most radiosensitive epidermis cells are located...

متن کامل

Linear model for physical activity prediction in healthy middle aged men

Introduction: The usage of valid, reliable, rapid and low cost instruments for measurement of physical activity (PA) volume are essential in epidemiological and clinical studies. The purpose of this study was to develop a new physical activity prediction model using physiological and anthropometric variables in middle aged men. Methods: Daily physical activity was measured with pedometer throug...

متن کامل

A literature review of electronic portal imaging for radiotherapy dosimetry.

Electronic portal imaging devices (EPIDs) have been the preferred tools for verification of patient positioning for radiotherapy in recent decades. Since EPID images contain dose information, many groups have investigated their use for radiotherapy dose measurement. With the introduction of the amorphous-silicon EPIDs, the interest in EPID dosimetry has been accelerated because of the favourabl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 47 11  شماره 

صفحات  -

تاریخ انتشار 2006