A twelve-channel automatic device for continuous recording of cell aggregation by measurement of small-angle light-scattering.
نویسندگان
چکیده
We describe here a 12-channel aggregometer, evolved from the instrument described by Beug & Gerisch in 1972, which records the course of aggregation or agglutination of cells or other particles by following the changes in light-scattering of the aggregating suspension. The instrument incorporates a simple memory system for condensing the data, introduces an improved cuvette design, and can be adjusted in its responsiveness to light-scattering by particles of different sizes. In our aggregometer, a vertical wheel in an opaque thermostatted chamber accommodates up to 12 cuvettes each containing a cell suspension and an air bubble. The constant rising of the bubble as the wheel rotates causes the stirring action which promotes aggregation. At a certain point in its rotational path, each cuvette is penetrated by a beam of light focused upon an absorbing beam stop centred in front of a photomultiplier tube. Particles suspended in the cuvette scatter a portion of the light beyond the beam stop into the photomultiplier tube to produce an electrical pulse proportional to the photon input. Collection of these pulses with the wheel in continuous motion avoids any disturbance of the course of aggregation. The pulses are routed to memory circuits for summation and eventual recording by a 12-channel printing potentiometer which automatically colour-codes and numbers each curve. The cuvettes consist of 2 glass microscope coverslips affixed with silicone grease over a hole in a thin, stainless steel blank. They are very durable and are easily dismantled and reassembled for cleaning. The coverslips are replaced after each use. The discoid chamber of our cuvette permits uniform circulation of the bubble, which in turn causes gentle stirring of the aggregating suspension at a rate that is a direct and continuous function of rev/min. Measurement of light-scattering at small angles (3--5.5 degrees) provides great sensitivity to the disappearance of single cells and progressively less sensitivity to the coalescence of aggregates of progressively larger size. The signal generated by the photomultipler tube decreases as aggregation proceeds. At 32 rev/min, one data point per channel, representing the sum (average) of 24 successive measurements, is printed every 45 s. In the course of a 60-min assay under standard conditions, up to 23040 individual readings can be automatically taken, summed and plotted. In a comparison of 8 identical samples run simultaneously, the printed values after 60 min agreed with a standard deviation of +/- 2%.
منابع مشابه
A Semi-Automatic Algorithm for Estimating Cobb Angle
Background: Scoliosis is the most common type of spinal deformity. A universal and standard method for evaluating scoliosis is Cobb angle measurement, but several studies have shown that there is intra- and inter- observer variation in measuring cobb angle manually.Objective: Develop a computer- assisted system to decrease operator-dependent errors in Cobb angle measurement.Methods: The spinal ...
متن کاملApplication of small angle X-ray scattering (SAXS) for differentiation between normal and cancerous breast tissues
ABSTRACT Background: Coherent scattering leads to diffraction effects and especially constructive interferences. Theseinterferences carry some information about the molecular structure of the tissue. As breast cancer isthe most widespread cancer in women, this project evaluated the application of small angleX-ray scattering (SAXS) for differentiation between normal and cancerous breast tissues....
متن کاملThe Aggregation Behavior of Short Chain Hydrophilic Ionic Liquids in Aqueous Solutions
In this paper, aggregation behaviors of aqueous solutions of short chain hydrophilic Ionic Liquids (ILs), 1 – allyl - 3 - methylimidazolium chloride ([Amim]Cl), 1 - ethyl - 3 - methylimidazolium chloride ([Emim]Cl), 1 - butyl - 3 - methylimidazolium chloride ([Bmim]Cl), 1 - butyl - 3 - methylimidazolium tetrafluoroborate ([Bmim]BF4) were investigated using conductivity and laser ...
متن کاملA Study on the Aggregation and Calf Thymus DNA Binding Characteristics of Anionic Cobalt(II) Tetrasulfonated Phthalocyanine
The aggregation behavior of anionic Cobalt(II) 4,4′,4ʺ,4‴-tetrasulfonated phthalocyanine, [Co(TSPc)4-] was studied at its various concentrations and different ionic strengths using optical absorption and resonance light scattering (RLS) spectroscopies in 5 mM phosphate buffer, pH 7.0 at 25 °C. The results show no aggregation behavior at concentration range of 5.1 × 10-6-7....
متن کاملDistance within colloidal dimers probed by rotation-induced oscillations of scattered light.
Aggregation processes of colloidal particles are of broad scientific and technological relevance. The earliest stage of aggregation, when dimers appear in an ensemble of single particles, is very important to characterize because it opens routes for further aggregation processes. Furthermore, it represents the most sensitive phase of diagnostic aggregation assays. Here, we characterize dimers b...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Journal of cell science
دوره 41 شماره
صفحات -
تاریخ انتشار 1980