Acoustic cardiac triggering: a practical solution for synchronization and gating of cardiovascular magnetic resonance at 7 Tesla
نویسندگان
چکیده
BACKGROUND To demonstrate the applicability of acoustic cardiac triggering (ACT) for imaging of the heart at ultrahigh magnetic fields (7.0 T) by comparing phonocardiogram, conventional vector electrocardiogram (ECG) and traditional pulse oximetry (POX) triggered 2D CINE acquisitions together with (i) a qualitative image quality analysis, (ii) an assessment of the left ventricular function parameter and (iii) an examination of trigger reliability and trigger detection variance derived from the signal waveforms. RESULTS ECG was susceptible to severe distortions at 7.0 T. POX and ACT provided waveforms free of interferences from electromagnetic fields or from magneto-hydrodynamic effects. Frequent R-wave mis-registration occurred in ECG-triggered acquisitions with a failure rate of up to 30% resulting in cardiac motion induced artifacts. ACT and POX triggering produced images free of cardiac motion artefacts. ECG showed a severe jitter in the R-wave detection. POX also showed a trigger jitter of approximately Δt = 72 ms which is equivalent to two cardiac phases. ACT showed a jitter of approximately Δt = 5 ms only. ECG waveforms revealed a standard deviation for the cardiac trigger offset larger than that observed for ACT or POX waveforms.Image quality assessment showed that ACT substantially improved image quality as compared to ECG (image quality score at end-diastole: ECG = 1.7 ± 0.5, ACT = 2.4 ± 0.5, p = 0.04) while the comparison between ECG vs. POX gated acquisitions showed no significant differences in image quality (image quality score: ECG = 1.7 ± 0.5, POX = 2.0 ± 0.5, p = 0.34). CONCLUSIONS The applicability of acoustic triggering for cardiac CINE imaging at 7.0 T was demonstrated. ACT's trigger reliability and fidelity are superior to that of ECG and POX. ACT promises to be beneficial for cardiovascular magnetic resonance at ultra-high field strengths including 7.0 T.
منابع مشابه
How much are atrial volumes and ejection fractions assessed by cardiac magnetic resonance imaging influenced by the ECG gating method?
PURPOSE Most magnetic resonance imaging (MRI) centers currently use prospective electrocardiographic (ECG) triggering for image acquisition. Retrospectively gated sequences allow the coverage of the entire cardiac cycle. It has been recently shown that ventricular volumes and ejection fraction (EF) differ according to the gating method used for image acquisition. The authors sought to evaluate ...
متن کاملImpact of the ECG gating method on ventricular volumes and ejection fractions assessed by cardiovascular magnetic resonance imaging.
PURPOSE Most MRI centers currently use prospective ECG triggering and fast gradient-echo sequences for image acquisition. Retrospectively gated sequences allow the coverage of the entire cardiac cycle. There is concern about whether ventricular volumes and ejection fraction (EF) differ according to the gating method used for image acquisition. We sought to evaluate the impact of the gating meth...
متن کاملVENTRICULAR FUNCTION Impact of the ECG gating method on ventricular volumes and ejection fractions assessed by cardiovascular magnetic resonance imaging
Purpose. Most MRI centers currently use prospective ECG triggering and fast gradient-echo sequences for image acquisition. Retrospectively gated sequences allow the coverage of the entire cardiac cycle. There is concern about whether ventricular volumes and ejection fraction (EF) differ according to the gating method used for image acquisition. We sought to evaluate the impact of the gating met...
متن کاملElectrocardiogram in an MRI Environment: Clinical Needs, Practical Considerations, Safety Implications, Technical Solutions and Future Directions
Magnetic Resonance Imaging (MRI) has been listed as the single most important medical innovation, on par with CT scanning (Fuchs & Sox 2001). In current clinical MRI ECG is being using for three major purposes. Firstly, heart motion, blood flow and blood pulsation are commonly dealt with using electrocardiogram (ECG) for synchronization of MR data acquisition with the cardiac cycle (Lanzer et.a...
متن کاملAssessment of the right ventricle with cardiovascular magnetic resonance at 7 Tesla
BACKGROUND Functional and morphologic assessment of the right ventricle (RV) is of clinical importance. Cardiovascular magnetic resonance (CMR) at 1.5T has become gold standard for RV chamber quantification and assessment of even small wall motion abnormalities, but tissue analysis is still hampered by limited spatial resolution. CMR at 7T promises increased resolution, but is technically chall...
متن کامل