Predicting dry eye using noninvasive techniques of tear film surface assessment.

نویسندگان

  • Dorota H Szczesna
  • David Alonso-Caneiro
  • D Robert Iskander
  • Scott A Read
  • Michael J Collins
چکیده

PURPOSE To measure tear film surface quality in healthy and dry eye subjects using three noninvasive techniques of tear film quality assessment and to establish the ability of these noninvasive techniques to predict dry eye. METHODS Thirty-four subjects participated in the study and were classified as dry eye or normal, based on standard clinical assessments. Three noninvasive techniques were applied for measurement of tear film surface quality: dynamic-area high-speed videokeratoscopy (HSV), wavefront sensing (DWS), and lateral shearing interferometry (LSI). The measurements were performed in both natural (NBC) and suppressed (SBC) blinking conditions. RESULTS To investigate the capability of each method to discriminate dry eye subjects from normal subjects, the receiver operating curve (ROC) was calculated and then the area under the curve (AUC) was extracted. The best result was obtained for the LSI technique (AUC = 0.80 in SBC and AUC = 0.73 in NBC), which was followed by HSV (AUC = 0.72 in SBC and AUC = 0.71 in NBC). The best result for DWS was an AUC of 0.64 obtained for changes in vertical coma in SBC, whereas for NBC, the results were poorer. CONCLUSIONS Noninvasive techniques of tear film surface assessment can be used for predicting dry eye, and such an assay can be achieved in NBC as well as SBC. In this study, LSI showed the best detection performance, closely followed by the dynamic-area HSV. The DWS technique was less powerful, particularly in NBC.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tear film stability: a review.

Tear film stability can be assessed via a number of tools designed for clinical as well as research purposes. These techniques can give us insights into the tear film, and allow assessment of conditions that can lead to dry eye symptoms, and in severe cases, to significant ocular surface damage and deterioration of vision. Understanding what drives tear film instability and its assessment is al...

متن کامل

The effect of low humidity on the human tear film.

PURPOSE To investigate the effect of exposure to a low relative humidity (RH) environment on tear film physiology. METHOD A controlled environment chamber was used to create 2 different environmental conditions. Ambient temperature was constant in both conditions (21°C) while the RH was set at 40% at the normal condition and at 5% in the desiccating environment. Tear evaporation, noninvasive ...

متن کامل

Automated Tear Film Surface Quality Breakup Time as a Novel Clinical Marker for Tear Hyperosmolarity in Dry Eye Disease.

PURPOSE To assess the diagnostic performance of a novel, automated, noninvasive measure of tear film stability derived from Placido disc videokeratography, the tear film surface quality breakup time (TFSQ-BUT), as a clinical marker for diagnosing dry eye disease (DED) relative to a standard of tear hyperosmolarity. METHODS This prospective, cross-sectional study involved 45 participants (28 D...

متن کامل

Noninvasive in vivo assessment of soft contact lens type on tear film surface quality.

PURPOSE To evaluate the effect of soft contact lens type on the in vivo tear film surface quality (TFSQ) on daily disposable lenses and to establish whether two recently developed techniques for noninvasive measurement of TFSQ can distinguish between different contact lens types. METHODS Thirteen subjects wearing four different types of daily soft contact lenses participated in the study. Dyn...

متن کامل

Objective optical assessment of tear-film quality dynamics in normal and mildly symptomatic dry eyes.

PURPOSE To evaluate and compare the tear-film dynamics in normal eyes and in eyes with mild dry-eye symptoms using a new noninvasive optical method based on a double-pass instrument. SETTING Hospital Universitario Virgen de la Arrixaca, Murcia, Spain. DESIGN Evaluation of diagnostic test or technology. METHODS Dynamic recording of double-pass retinal images during unforced tear-film break...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Investigative ophthalmology & visual science

دوره 52 2  شماره 

صفحات  -

تاریخ انتشار 2011