Temporary hearing threshold shift measured by otoacoustic emissions in subjects exposed to short-term impulse noise.

نویسندگان

  • Jurek Olszewski
  • Jarosław Miłoński
  • Wiesław J Sułkowski
  • Joanna Majak
  • Sławomir Olszewski
چکیده

OBJECTIVES The aim of the study was to assess the influence of short-term impulse noise on the size and dynamics of temporary threshold shift, which precedes permanent threshold shift, i.e. noise-induced hearing loss. It was hoped to use the findings for preventive activities. MATERIALS AND METHODS The study included 80 healthy subjects (160 ears), aged 19-23 years, divided into two groups: group I comprised 40 recruit soldiers put to the shooting training, and group II consisted of 40 young male controls. All subjects had to show normal hearing with pure tone audiometric thresholds between 10-15 dB. Transient evoked otoacoustic emission (TOAE) measurements were performed by ILO 292 Echoport Otodynamics device 3-5 min before shooting and then 2 min, 1, 2 and 3 h, respectively after shooting. In group II the time intervals were similar. RESULTS It was found that the gunshot impulse noise from the kbk AKMS rifle caused temporary hearing threshold shift (TTS) at 1, 2, 3, 4 and 5 kHz frequencies of 1.07, 0.96, 1.41, 0.88 and 1.25 dB SPL, respectively. TIS turned out to be maximum at 4 and 5 kHz and minimum at 1 and 2 kHz. CONCLUSIONS Short-term impulse noise generated by the rifle gunshots induces rather small temporary threshold shift of hearing. Anyhow, considering possibilities of different weapon noises in the military environment as well as various sources of industrial impulse noise, the usage of hearing protectors should be highly recommended.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Temporary changes in hearing after exposure to shooting noise.

OBJECTIVES Firearm is a common source of impulse noise that may potentially damage hearing organ. It has been suggested that otoacoustic emissions, particularly transient-evoked otoacoustic emissions (TEOAE), might be more sensitive than pure-tone audiometry (PTA) in the assessment of changes to cochlea caused by noise. The aim of this study was to: (i) evaluate exposure to impulse noise from s...

متن کامل

Effects of Co-Exposure to Noise and JP-4 Jet Fuel on Hearing Loss in Rats

Background and Aim: Autotoxic substances such as JP-4 jet fuel can have negative effects on the auditory system by the various means such as cochlear dysfunction. The purpose of this study was to investigate the combined effects of exposure to JP-4 jet fuel and noise on hearing loss in rats, to determine the possible interference effects of these two risk factors on rat auditory system. Methods...

متن کامل

The Effect of Celecoxib, a Cyclooxygenase-2 Inhibitor on Noise- Induced Hearing Loss

Objective(s): Noise-induced hearing loss (NIHL) is the major cause of acquired hearing loss.  Celecoxib, a cyclooxygenase-2 (COX-2) inhibitor, is a non- steroidal anti- inflammatory drug (NSAID) with known antioxidant and antineoplastic activity. Therefore, we monitored the extent of temporary noise- induced threshold shifts (TTS) and cochlear damage caused by high level 4- kHz noise exposure t...

متن کامل

Auditory monitoring by means of evaluation of the cochlea in soldiers of the Brazilian Army exposed to impulse noise.

INTRODUCTION Exposure to continuous or impulse noise may lead to High Sound Pressure Induced Hearing Loss (HSPIHL) or to acoustic trauma in soldiers. Auditory evaluation by means of evoked otoacoustic emissions (EOAE) has been demonstrating its importance in the detection of subtle changes in cochlear function still unidentified in threshold tone audiometry in subjects exposed to noise. OBJEC...

متن کامل

Transient-evoked otoacoustic emissions as a measure of noise-induced threshold shift.

Otoacoustic emissions and behavioral hearing thresholds were measured before and after exposure to a 10-min, 105-dB SPL, half-octave band of noise centered at 1.414 kHz. Along a single recovery function, transient-evoked otoacoustic-emission (TEOAE) measurements made with 74-dB pSPL nonlinear click ensembles were alternated with a Bekesy threshold-tracking procedure. Each of the 14 participants...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • International journal of occupational medicine and environmental health

دوره 18 4  شماره 

صفحات  -

تاریخ انتشار 2005