Comparative Evaluation of the Effect of Manufacturing Process on Distortion of Rotary ProFile and Twisted File: An in Vitro SEM Study

نویسندگان

  • Swati Sharma
  • Rajendra Kumar Tewari
  • Pankaj Kharade
  • Pankaj Kharade
چکیده

Background and aims. The manufacturing process of rotary Ni-Ti file can influence its resistance to fracture. The rotary ProFile (Dentsply-Maillefer, Baillagues, Switzerland) is manufactured by grinding mechanism whereas Twisted File (Sy-bron Endo, USA) is manufactured with a twisting method. The purpose of this study was to comparatively evaluate the effect of manufacturing process on distortion of rotary ProFile and Twisted files using scanning electron microscopy after in vitro use. Materials and methods. Five sets of each type of file were used for this study -rotary ProFile (group A) and Twisted file (group B). Each set was used according to manufacturer's instructions to prepare 5 mesial canals of extracted mandibular molars. The changes in files were observed under a scanning electron microscope at ×18, ×100, ×250 and ×500 magnifications. Observations were classified as intact with no discernible distortion, intact but with unwinding, and fractured. Group A and B were then compared for deformation and fracture using two-proportion z-test. Results. On SEM observation, used rotary ProFile showed microfractures along the machining grooves whereas Twisted file showed crack propagation that was perpendicular to the machining marks. On statistical analysis, no significant difference was found between ProFile and Twisted file for deformation (P=0.642) and fracture (P=0.475). Conclusion. Within the experimental protocol of this study, it was concluded that both ProFile and Twisted files exhibited visible sign of distortion before fracture. But Twisted file gained edge over ProFile because of its manufacture design and unparalleled resistance to breakage.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparative study on canal preparation by three rotary sys-tems using CT scan (An in vitro study)

Comparative study on canal preparation by three rotary sys-tems using CT scan (An in vitro study) Dr. M.H. Zarrabi* - Dr. A. Talati** - Dr. S. Moradi** - Dr. L. Shakeri*** * - Associate Professor and Chief of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Sciences. **- Assistant Professor of Endodontics Dept. - Faculty of Dentistry – Mashhad University of Medical Scien...

متن کامل

Comparative evaluation of fracture and defect in reciproc and rotary files in severe curved root canals

Introduction: Root canal instrumentation is an important phase in root canal therapy. Since success in endodontic treatment depends on file defect and fracture, the aim of this study was to compare the evaluation of defect and fracture in rotary and reciproc files in severe curved root canals. Materials & Methods: In this experimental study, 60 mesial canals of human closed apex molars with ...

متن کامل

A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro)

A comparison of transportation and time of canal preparation with stainless steel hand instruments and Ni-Ti rotary systems (In – Vitro) Dr. MR. Sharifian* - Dr. MH. Nekoofar* - Dr. P. Motahari** - Dr. A. Tavakoli*** *-Assistant Professor of Endodontics Dept. – Faculty of Dentistry – Tehran University of Medical Sciences. **- Assistant Professor of Oral and Maxillofacial Pathology Dept. – Facul...

متن کامل

A comparative study of the cleaning effect of various ultrasonic cleaners on ‎new, unused endodontic instruments

BACKGROUND AND AIM: This study was carried out to compare three different ultrasonic cleaner devices in the cleaning process of endodontic instruments by scanning electron microscope (SEM). METHODS: In this study, 120 unused brand new hand and rotary instruments were examined after removing from the sealed package. The instruments were randomly divided into six groups of 20 rotary or hand files...

متن کامل

Comparative Evaluation of Physical Surface Changes and Incidence of Separation in Rotary Nickel-Titanium Instruments: An in Vitro SEM Study

INTRODUCTION The aim of the present study was to comparatively evaluate the physical surface changes and incidence of separation in rotary nickel-titanium (NiTi) instruments using scanning electron microscope (SEM). METHODS AND MATERIALS A total number of 210 freshly extracted human maxillary and mandibular first molars were selected and distributed between three groups. Three different syste...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2015