Contamination of stethoscopes and physicians' hands after a physical examination.
نویسندگان
چکیده
OBJECTIVES To compare the contamination level of physicians' hands and stethoscopes and to explore the risk of cross-transmission of microorganisms through the use of stethoscopes. PATIENTS AND METHODS We conducted a structured prospective study between January 1, 2009, and May 31, 2009, involving 83 inpatients at a Swiss university teaching hospital. After a standardized physical examination, 4 regions of the physician's gloved or ungloved dominant hand and 2 sections of the stethoscopes were pressed onto selective and nonselective media; 489 surfaces were sampled. Total aerobic colony counts (ACCs) and total methicillin-resistant Staphylococcus aureus (MRSA) colony-forming unit (CFU) counts were assessed. RESULTS Median total ACCs (interquartile range) for fingertips, thenar eminence, hypothenar eminence, hand dorsum, stethoscope diaphragm, and tube were 467, 37, 34, 8, 89, and 18, respectively. The contamination level of the diaphragm was lower than the contamination level of the fingertips (P<.001) but higher than the contamination level of the thenar eminence (P=.004). The MRSA contamination level of the diaphragm was higher than the MRSA contamination level of the thenar eminence (7 CFUs/25 cm(2) vs 4 CFUs/25 cm(2); P=.004). The correlation analysis for both total ACCs and MRSA CFU counts revealed that the contamination level of the diaphragm was associated with the contamination level of the fingertips (Spearman's rank correlation coefficient, ρ=0.80; P<.001 and ρ=0.76; P<.001, respectively). Similarly, the contamination level of the stethoscope tube increased with the increase in the contamination level of the fingertips for both total ACCs and MRSA CFU counts (ρ=0.56; P<.001 and ρ=.59; P<.001, respectively). CONCLUSION These results suggest that the contamination level of the stethoscope is substantial after a single physical examination and comparable to the contamination of parts of the physician's dominant hand.
منابع مشابه
Comments on "Study of Bacterial Contamination of Mobile Phones and Stethoscopes in Neonatal Intensive Care Unit"
This letter is regarding the article by Daoudi et al. entitled "Study of bacterial contamination of mobile phones and stethoscopes in Neonatal Intensive Care Unit" published in International Journal of Pediatrics DOI: 10.22038/IJP.2017.25504.2170 (1). The authors have evaluated the microbial contamination of mobile phones and stethoscopes used by medical and paramedical staff. They reported tha...
متن کاملEvidence-based health care for all: support from the Brazilian Ministry of Health.
As you well know, after Semmelweis made the fundamental discovery of the cause of puerperal infection (contamination from doctors’ hands), he died as a “madman” in a hospital, tormented by the lack of comprehension of his findings. His colleagues, who had been performing puerperal examinations without antiseptic procedures for so long, did not believe the new evidence. Even today, it is known t...
متن کاملBacterial contamination of stethoscopes used by health workers: public health implications.
BACKGROUND This study was designed to assess both the potential for bacterial transmission by stethoscopes used by health-care workers in Nigeria and the implications for patient safety and control of hospital-acquired infections. METHODOLOGY A structured questionnaire was administered to health workers and the surface of the diaphragm of their stethoscopes swabbed for bacteriological analysi...
متن کاملContamination Level of Stethoscopes Used By Physicians and Physician Assistants
The Journal of Physician Assistant Education | 2007 Vol 18 No 2 INTRODUCTION The stethoscope is a popular instrument used by health care providers to evaluate the lung, heart, and abdominal sounds of their patients. Although clinicians are instructed about microbiology and the importance of maintaining clean medical instruments, the stethoscope may not be thought of as a potential source of nos...
متن کاملStudy of Bacterial Contamination of Mobile Phones and Stethoscopes in Neonatal Intensive Care Unit
Mobile phones and stethoscopes used in neonatology units could be colonized by potentiel bacteria pathogens. It can be a vector of severe nosocomial infections and multi-drug-resistant pathogens. The aim of this study is to evaluate the microbial contamination of mobile phones and stethoscopes, used by medical and paramedical staff. The study was conducted in neonatal intensive care unit (NICU)...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Mayo Clinic proceedings
دوره 89 3 شماره
صفحات -
تاریخ انتشار 2014