Cervical length measured by transvaginal ultrasonography versus Bishop score to predict successful labour induction in term pregnancies

نویسندگان

  • Y.J.B. Groeneveld
  • A.M. Bohnen
  • A.M. Van Heusden
چکیده

OBJECTIVES To compare the value of transvaginal ultrasonographic measurement of the cervical length versus the Bishop score, prior to induction of labour, in predicting the mode of delivery within four days. MATERIALS AND METHODS This longitudinal study included 110 women (at term, singleton, vertex presentation) in whom induction of labour was performed at 37-42 weeks of gestation. Cervical length on transvaginal ultrasound and the Bishop score were assessed prior to induction according to standard protocol. Medical records were reviewed for relevant-- demographic and clinical data. Primary outcome criterion was successful vaginal delivery within 96 h. Univariate analyses and receiver operating characteristic (ROC) curves were used to examine differences between variables possibly predicting outcome. RESULTS Of the 110 women 66 were nulliparous and 44 multiparous. Vaginal delivery within 96 h was successful in 48 (73%) nulliparous and in 40 (91%) multiparous women ( i.e. in 80% of the total population). The overall rate of caesarean delivery was 17%. THERE WAS A SIGNIFICANT DIFFERENCE BETWEEN NULLIPAROUS AND MULTIPAROUS WOMEN IN AGE, CERVICAL LENGTH (MEAN IN MM IN NULLIPAROUS WOMEN: 29.31, range: 5.00-56.00; in multiparous women: 37.04, range: 12.00-56.00), Bishop score and successful induction, but no significant difference between these subgroups in neonatal outcomes. Only the Bishop score in nulliparous women showed a significant relationship between this variable and predicting successful labour induction (area under the ROC curve 0.679; standard error 0.73; p < 0.05; 95% CI: 0.536-0.823). The best cut-off value for the Bishop score was 3, with a sensitivity of 56.3% and a specificity of 72.2%. CONCLUSION In this study group significant independent prediction of vaginal delivery within 96 h is provided by the Bishop score but only in nulliparous women. Transvaginal ultrasonographic measurement of cervical length is not a significant independent predictor of vaginal delivery within 96 h.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvaginal ultrasonography compared with Bishop score for predicting cesarean section after induction of labor

BACKGROUND Reproductive health researchers are interested in finding better methods for predicting an unwanted type of delivery after induction of labor. The aim of this study was to compare the value of transvaginal ultrasonography findings and the Bishop score in predicting cesarean section after induction of labor. METHODS Two hundred women with singleton pregnancies undergoing induction o...

متن کامل

Insulin-like growth factor binding protein 1, Bishop score, and sonographic cervical length: tolerability and prediction of vaginal birth and vaginal birth within 24 hours following labour induction in nulliparous women.

OBJECTIVE To evaluate the tolerability of cervical insulin-like growth factor binding protein 1 (IGFBP-1) and its value as a predictor of successful labour induction, compared with Bishop score and transvaginal ultrasound (TVUS) cervical length. DESIGN A prospective study. SETTING A tertiary hospital in Malaysia. POPULATION A cohort of 193 term nulliparous women with intact membranes. M...

متن کامل

Transvaginal sonographic measurement of cervical length vs. Bishop score in labor induction at term: tolerability and prediction of Cesarean delivery.

OBJECTIVES To compare transvaginal sonography for cervical length measurement and digital examination for Bishop score assessment in women undergoing labor induction at term, to assess their tolerability (in terms of pain) and ability to predict need for Cesarean delivery. METHODS A prospective study was performed on 249 women admitted for labor induction. Cervical length was measured using t...

متن کامل

Ultrasound and clinical predictors for Caesarean delivery after labour induction at term.

OBJECTIVE To assess the relationship of ultrasound assessment for amniotic fluid, fetal weight, cervical length, cervical funneling and clinical factors on the risk of Caesarean delivery after labour induction at term. METHODS On hundred and fifty-two women scheduled for labour induction at term agreed to participate. Sonography was performed to obtain fetal biometry, amniotic fluid index and...

متن کامل

Sonographically accessed funneling of the uterine cervix as a predictor of successful labor induction

OBJECTIVE The Bishop score and length of the uterine cervix are good predictors of successful labor induction. However, little is known about the association between the funneling of the uterine cervix and successful labor induction. The study aimed to evaluate cervical funneling as a predictor of successful labor induction. METHODS This study was designed as a prospective observational study...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2010