Defining the boundaries of bedside pulse contour analysis: dynamic arterial elastance

نویسنده

  • Michael R Pinsky
چکیده

Assessment of vasomotor tone is essential in defining appropriate resuscitation strategies for the hypotensive patient. Although changes in mean arterial pressure to cardiac output define arterial resistance, resistance is only one component of vasomotor tone. Compliance is the other component. The reciprocal of compliance is arterial elastance (Ea). Importantly, dynamic Ea can be estimated by the pulse pressure variation to stroke volume variation relation. Dynamic Ea is only one component of vasomotor tone, however, and increases in pulse pressure may not be proportional to increases in mean arterial pressure. Also, devices that use the arterial pressure pulse to calculate the stroke volume have an inherent bias that is different amongst devices based on their transfer function algorithms. The use of dynamic Ea for clinical decision-making thus needs to be validated separately for different devices and types of patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

0590. Impact of arterial tone changes on dynamic arterial elastance and the arterial pressure response to fluid administration

Introduction Dynamic arterial elastance (Eadyn), the relationship between pulse pressure variation (PPV) and stroke volume variation (SVV), has been suggested as a functional assessment of arterial load for predicting the arterial pressure response after volume expansion (VE). Although changes in Eadyn have been related with variations in arterial load, the effect of acute arterial tone changes...

متن کامل

Bedside and continuous assessment of arterial load in critically-ill patients by combined analysis of esophageal doppler blood flow and arterial pressure waveform: preliminary results

Objectives To test the usefulness of continuous assessment of arterial load based on a 3-element Windkessel model by a combined analysis of the esophageal Doppler derived-blood flow and arterial pressure waveform, against standard frequency-domain analysis of arterial impedance. Methods Time-domain variables of arterial impedance were obtained by the simultaneous analysis of the Doppler derived...

متن کامل

Dynamic arterial elastance predicts mean arterial pressure decrease associated with decreasing norepinephrine dosage in septic shock

INTRODUCTION Gradual reduction of the dosage of norepinephrine (NE) in patients with septic shock is usually left to the physician's discretion. No hemodynamic indicator predictive of the possibility of decreasing the NE dosage is currently available at the bedside. The respiratory pulse pressure variation/respiratory stroke volume variation (dynamic arterial elastance (Eadyn)) ratio has been p...

متن کامل

Cardiac Output Monitoring by Pulse Contour Analysis, the Technical Basics of Less-Invasive Techniques

Routine use of cardiac output (CO) monitoring became available with the introduction of the pulmonary artery catheter into clinical practice. Since then, several systems have been developed that allow for a less-invasive CO monitoring. The so-called "non-calibrated pulse contour systems" (PCS) estimate CO based on pulse contour analysis of the arterial waveform, as determined by means of an art...

متن کامل

Pulse pressure variation, stroke volume variation and dynamic arterial elastance

Which means that SVV (%) ≈ pulse pressure variation (PPV; %) for FloTracTM. With the present mathematical equation, it can be demonstrated that the SVV calculated by FloTracTM (SVVFT) is not infl uenced by Khi, which means that SVVFT calculation does not include eff ective arterial elastance (Ea). Th e originality of Garcia and colleagues’ fi nding is that they realized that when measuring PPV ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 15  شماره 

صفحات  -

تاریخ انتشار 2011