Left univentricular pacing for cardiac resynchronization therapy using rate-adaptive atrioventricular delay

نویسندگان

  • Li-Jin Pu
  • Yu Wang
  • Lu-Lu Zhao
  • Tao Guo
  • Shu-Min Li
  • Bao-Tong Hua
  • Ping Yang
  • Jun Yang
  • Yan-Zhou Lu
  • Liu-Qing Yang
  • Ling Zhao
  • Hai-Yun Luo
چکیده

OBJECTIVE To evaluate left univentricular (LUV) pacing for cardiac resynchronization therapy (CRT) using a rate-adaptive atrioventricular delay (RAAVD) algorithm to track physiological atrioventricular delay (AVD). METHODS A total of 72 patients with congestive heart failure (CHF) were randomized to RAAVD LUV pacing versus standard biventricular (BiV) pacing in a 1: 1 ratio. Echocardiography was used to optimize AVD for both groups. The effects of sequential BiV pacing and LUV pacing with optimized A-V (right atrio-LV) delay using an RAAVD algorithm were compared. The standard deviation (SD) of the S/R ratio in lead V1 at five heart rate (HR) segments (RS/R-SD5), defined as the "tracking index," was used to evaluate the accuracy of the RAAVD algorithm for tracking physiological AVD. RESULTS The QRS complex duration (132 ± 9.8 vs. 138 ± 10 ms, P < 0.05), the time required for optimization (21 ± 5 vs. 50 ± 8 min, P < 0.001), the mitral regurgitant area (1.9 ± 1.1 vs. 2.5 ± 1.3 cm2, P < 0.05), the interventricular mechanical delay time (60.7 ± 13.3 ms vs. 68.3 ± 14.2 ms, P < 0.05), and the average annual cost (13,200 ± 1000 vs. 21,600 ± 2000 RMB, P < 0.001) in the RAAVD LUV pacing group were significantly less than those in the standard BiV pacing group. The aortic valve velocity-time integral in the RAAVD LUV pacing group was greater than that in the standard BiV pacing group (22.7 ± 2.2 vs. 21.4 ± 2.1 cm, P < 0.05). The RS/R-SD5 was 4.08 ± 1.91 in the RAAVD LUV pacing group, and was significantly negatively correlated with improved left ventricular ejection fraction (LVEF) (ΔLVEF, Pearson's r = -0.427, P = 0.009), and positively correlated with New York Heart Association class (Spearman's r = 0.348, P = 0.037). CONCLUSIONS RAAVD LUV pacing is as effective as standard BiV pacing, can be more physiological than standard BiV pacing, and can decrease the average annual cost of CRT.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Left Univentricular Pacing by Rate-Adaptive Atrioventricular Delay in Treatment of Chronic Heart Failure

BACKGROUND Cardiac resynchronization therapy (CRT) is efficacious in the treatment of chronic heart failure (CHF); however, because it is non-physiological, some patients are unresponsive. The present study used rate-adaptive atrioventricular delay (RAAVD) to track the physiological atrioventricular delay and investigated the effects of left univentricular pacing on CRT. MATERIAL AND METHODS Pa...

متن کامل

Echocardiographic optimization of the atrioventricular and interventricular intervals during cardiac resynchronization.

An optimized atrioventricular (AV) interval can maximize the benefits of cardiac resynchronization therapy (CRT). If programmed poorly, it may curtail beneficial effects of CRT. AV optimization will not convert non-responder to responder, but may convert under-responder to improved status. There are many echocardiographic techniques for AV optimization but there is no universally accepted gold ...

متن کامل

Programming Cardiac Resynchronization Therapy for Electrical Synchrony: Reaching Beyond Left Bundle Branch Block and Left Ventricular Activation Delay

BACKGROUND QRS narrowing following cardiac resynchronization therapy with biventricular (BiV) or left ventricular (LV) pacing is likely affected by patient-specific conduction characteristics (PR, qLV, LV-paced propagation interval), making a universal programming strategy likely ineffective. We tested these factors using a novel, device-based algorithm (SyncAV) that automatically adjusts paced...

متن کامل

Adaptive cardiac resynchronization therapy for dilated cardiomyopathy with functional mitral regurgitation

We report the case of a man in his 60s who had dilated cardiomyopathy with severe functional mitral regurgitation. Four years after a cardiac resynchronization therapy (CRT) device with an implantable cardioverter defibrillator was implanted, this device was replaced with an adaptive CRT device because of battery consumption. Seven months after replacement of this device, the left ventricular p...

متن کامل

Pacing in heart failure: the benefit of resynchronization.

Cardiac resynchronization therapy involves pacing of the left ventricle alone or in concert with the right ventricle within a certain range of atrioventricular delay. It may help patients with systolic heart failure and conduction disturbances by optimizing myocardial performance.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 14  شماره 

صفحات  -

تاریخ انتشار 2017