Automatic Non-rigid Temporal Alignment of IVUS Sequences

نویسندگان

  • Marina Alberti
  • Simone Balocco
  • Xavier Carrillo
  • Josepa Mauri
  • Petia Radeva
چکیده

Clinical studies on atherosclerosis regression/progression performed by intravascular ultrasound analysis require the alignment of pullbacks of the same patient before and after clinical interventions, In this paper, a methodology for the automatic alignment of IVUS sequences based on the dynamic time warping technique is proposed. The method is adapted to the specific IVUS alignment task by applying the non-rigid alignment technique to multidimensional morphological signals, and by introducing a sliding window approach together with a regularization term. To show the effectiveness of our method, an extensive validation is performed both on synthetic data and in-vivo IVUS sequences. The proposed method is robust to stent deployment and post dilation surgery and reaches an alignment error of approximately 0.7 mm for in-vivo data, which is comparable to the inter-observer variability.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

4D Match Trees for Non-rigid Surface Alignment

This paper presents a method for dense 4D temporal alignment of partial reconstructions of non-rigid surfaces observed from single or multiple moving cameras of complex scenes. 4D Match Trees are introduced for robust global alignment of non-rigid shape based on the similarity between images across sequences and views. Wide-timeframe sparse correspondence between arbitrary pairs of images is es...

متن کامل

Spatio-temporal (2D+T) non-rigid registration of real-time 3D echocardiography and cardiovascular MR image sequences.

In this paper we describe a method to non-rigidly co-register a 2D slice sequence from real-time 3D echocardiography with a 2D cardiovascular MR image sequence. This is challenging because the imaging modalities have different spatial and temporal resolution. Non-rigid registration is required for accurate alignment due to imprecision of cardiac gating and natural motion variations between card...

متن کامل

Modelling of image-catheter motion for 3-D IVUS

Three-dimensional intravascular ultrasound (IVUS) allows to visualize and obtain volumetric measurements of coronary lesions through an exploration of the cross sections and longitudinal views of arteries. However, the visualization and subsequent morpho-geometric measurements in IVUS longitudinal cuts are subject to distortion caused by periodic image/vessel motion around the IVUS catheter. Us...

متن کامل

Robust Spatio-Temporal Registration of 4D Cardiac Ultrasound Sequences.

Registration of multiple 3D ultrasound sectors in order to provide an extended field of view is important for the appreciation of larger anatomical structures at high spatial and temporal resolution. In this paper, we present a method for fully automatic spatio-temporal registration between two partially overlapping 3D ultrasound sequences. The temporal alignment is solved by aligning the norma...

متن کامل

Vessel Structures Alignment by Spectral Analysis of IVUS Sequences

IntraVascular UltraSound is an imaging technique very helpful for the diagnosis and treatment of cardiac diseases, since it allows the visualization of vessel morphology together with vessel geometry and dynamics induced by heart motion. Non rigid arterial deformation is of clinical interest, since it serves to measure vessel wall stiffness and, through elastographic analysis, to determine vess...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical image computing and computer-assisted intervention : MICCAI ... International Conference on Medical Image Computing and Computer-Assisted Intervention

دوره 15 Pt 1  شماره 

صفحات  -

تاریخ انتشار 2012