AIMS Typically, myocardial perfusion imaging with two-dimensional (2D) cardiovascular magnetic resonance (CMR) acquires data in three to four myocardial slices at a spatial resolution of 2-3 mm. However, accelerated data acquisition can facilitate higher spatial resolution (<2 mm) or three-dimensional (3D) whole-heart coverage (up to 16 slices). This study aims to compare image quality, diagnostic confidence, and quantitation of myocardial ischaemic burden (MIB) between 2D high-resolution and 3D whole-heart perfusion-CMR. METHODS AND RESULTS Twenty-seven patients with stable angina underwent both high-resolution 2D and whole-heart 3D perfusion-CMR. Total perfusion defect (TPD) and total scar burden (TSB) areas were contoured and expressed as percentage myocardium. MIB was calculated by subtracting TSB from TPD. Image quality, artefact, and diagnostic confidence scores were similar for both techniques (P>0.05). The mean MIB from high-resolution and 3D acquisition was similar (4.3±5.2% vs. 4.1±4.9%; P=0.81), with a strong correlation between techniques (r=0.72; P<0.001). There was no systematic bias for estimates of MIB between techniques [mean bias=-0.17%, 95% confidence interval (CI): -1.7 to -1.3%] and the 95% limits of agreement were -7.5 to 7.2%. When used to categorize MIB as >10% or <10%, there was only fair agreement between the two techniques (κ=0.29, 95% CI: -0.12 to 0.70). CONCLUSION There is strong correlation and broad agreement between estimates of MIB from both techniques. However, the 95% limits of agreement are relatively wide and therefore a larger comparative study is needed before they can be considered interchangeable-particularly around the clinically relevant 10% threshold.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Quantification of perfusion defects with high resolution 2D and 3D adenosine stress perfusion 3.0 Tesla CMR

Background Myocardial ischaemic burden is an important marker of outcome in stable ischaemic heart disease with a 10% ischaemic burden suggested as a clinically relevant threshold for revascularisation. Standard CMR stress perfusion imaging utilises 3 short axis slices, each acquired in different phases of the cardiac cycle. Recently proposed 3D myocardial perfusion CMR allows the entire myocar...

متن کامل

Whole-heart dynamic three-dimensional magnetic resonance perfusion imaging for the detection of coronary artery disease defined by fractional flow reserve: determination of volumetric myocardial ischaemic burden and coronary lesion location.

AIMS Dynamic three-dimensional-cardiac magnetic resonance (3D-CMR) perfusion proved highly diagnostic for the detection of angiographically defined coronary artery disease (CAD) and has been used to assess the efficacy of coronary stenting procedures. The present study aimed to relate significant coronary lesions as assessed by fractional flow reserve (FFR) to the volume of myocardial hypoenhan...

متن کامل

Myocardial ischaemic burden assessed by three-dimensional perfusion CMR - comparison with Myocardial Perfusion Scintigraphy

Background Myocardial ischaemic burden assessed by myocardial perfusion scintigraphy (MPS) is commonly used to riskstratify patients with suspected coronary artery disease (CAD). Accurate estimation of ischaemic burden by CMR with two-dimensional imaging is limited by incomplete myocardial coverage to a small number (usually three) of non-contiguous sections. The aim of this study was to compar...

متن کامل

Assessment of ischaemic burden in angiographic three-vessel coronary artery disease with high-resolution myocardial perfusion cardiovascular magnetic resonance imaging

AIMS This study compared the myocardial ischaemic burden (MIB) in patients with angiographic three-vessel coronary artery disease (3VD) using high-resolution and standard-resolution myocardial perfusion cardiovascular magnetic resonance (perfusion CMR) imaging. METHODS AND RESULTS One hundred and five patients undergoing coronary angiography had two separate stress/rest perfusion CMR studies,...

متن کامل

Validation of dynamic three-dimensional whole heart magnetic resonance myocardial perfusion imaging against single photon emission computed tomography for the detection of functionally significant coronary heart disease

We demonstrate the feasibility of 3D myocardial perfusion CMR at 3 Tesla against single photon emission computer tomography for the detection and estimate of ischaemic burden and show good agreement between the techniques. This novel technique shows promising use of this method in a small cohort of patients to estimate ischaemic burden for purpose of risk stratification of patients with known o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • European heart journal cardiovascular Imaging

دوره 17 8  شماره 

صفحات  -

تاریخ انتشار 2016