Pressure-dependent attenuation and scattering of phospholipid-coated microbubbles at low acoustic pressures.

نویسندگان

  • Marcia Emmer
  • Hendrik J Vos
  • David E Goertz
  • Annemieke van Wamel
  • Michel Versluis
  • Nico de Jong
چکیده

Previous optical studies have shown threshold behavior of single-contrast agent microbubbles. Below the acoustic pressure threshold, phospholipid-coated microbubbles with sizes <5.0 mum in diameter oscillate significantly less than above the threshold pressure. Previous studies also revealed an acoustic pressure-dependent attenuation of ultrasound by microbubble contrast agents. In this study, we investigated whether pressure-dependent acoustic behavior may be explained by threshold behavior. For this purpose, pressure-dependent attenuation and scattering of a phospholipid-coated contrast agent were measured. Transmit frequencies between 1.5 and 6.0 MHz and acoustic pressures between 5 and 200 kPa were applied. Unlike the galactose-based contrast agent Levovist, the phospholipid-coated contrast agent BR14 showed a pressure-dependent attenuation. In addition, it was found that filtered suspensions with only microbubbles <3.0 mum in diameter show more pressure-dependent attenuation behavior than native suspensions of phospholipid-coated microbubbles. For the scattering measurements conducted at 3.0 MHz, the native suspension did not show any pressure-dependent behavior. However, the filtered suspension responded highly nonlinearly. Between 30 and 150 kPa, 16 dB additional scattered power was obtained. We concluded that threshold behavior of phospholipid-coated microbubbles results in pressure-dependent attenuation and scattering.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Frequency and pressure dependent attenuation and scattering by microbubbles.

The aim of this study was to evaluate experimentally the degree of pressure dependence of attenuation and scattering by microbubbles at low acoustic pressures with an empirical nonlinear model. In addition, the pressure dependency over a range of frequencies (1 to 5 MHz) has been studied. A series of transmission and scattering measurements were made with the microbubble SonoVue, using an autom...

متن کامل

Investigation of acoustic properties of silica coated gold nanoparticle as contrast agent for Ultrasonography

Interoduction: Ultrasound images have often low contrast due to small differences in acoustic impedance between different tissues. Air or gas microbubbles that surrounded by membrane are most of the contrast agents in ultrasound imaging. Problems such as instability in sound pressure and inability in penetrating from the blood vessel into body tissues limited the use of microbubbles into the in...

متن کامل

Subharmonic behavior of phospholipid-coated ultrasound contrast agent microbubbles.

Coated microbubbles, unlike tissue are able to scatter sound subharmonically. Therefore, the subharmonic behavior of coated microbubbles can be used to enhance the contrast in ultrasound contrast imaging. Theoretically, a threshold amplitude of the driving pressure can be calculated above which subharmonic oscillations of microbubbles are initiated. Interestingly, earlier experimental studies o...

متن کامل

Blood Brain Barrier Disruption by Focused Ultrasound and Microbubbles: A Numerical Study on Mechanical Effects

Introduction: Microbubbles are widely used as contrast agent in diagnostic ultrasound. Recently they have shown good potential for applications in the therapeutic field such as drug delivery to the brain. Recent studies have shown focused ultrasound in conjunction with injected micro-bubbles could temporarily disrupt blood-brain barrier and let therapeutic agents transport into...

متن کامل

Effect of ultrasound on adherent microbubble contrast agents.

An investigation into the effect of clinical ultrasound exposure on adherent microbubbles is described. A flow phantom was constructed in which targeted microbubbles were attached using biotin-streptavidin linkages. Microbubbles were insonated by broadband imaging pulses (centred at 2.25 MHz) over a range of pressures (peak negative pressure (PNP) = 60-375 kPa). Individual adherent bubbles were...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultrasound in medicine & biology

دوره 35 1  شماره 

صفحات  -

تاریخ انتشار 2009