Reference values for spirometry – report from the Obstructive Lung Disease in Northern Sweden studies

نویسندگان

  • Helena Backman
  • Anne Lindberg
  • Anders Odén
  • Linda Ekerljung
  • Linnéa Hedman
  • Annette Kainu
  • Anssi Sovijärvi
  • Bo Lundbäck
  • Eva Rönmark
چکیده

BACKGROUND Abnormal lung function is commonly identified by comparing observed spirometric values to corresponding reference values. It is recommended that such reference values for spirometry are evaluated and updated frequently. The aim of this study was to estimate new reference values for Swedish adults by fitting a multivariable regression model to a healthy non-smoking general population sample from northern Sweden. Further aims were to evaluate the external validity of the obtained reference values on a contemporary sample from south-western Sweden, and to compare them to the Global Lung Function Initiative (GLI) reference values. METHOD Sex-specific multivariable linear regression models were fitted to the spirometric data of n=501 healthy non-smoking adults aged 22-91 years, with age and height as predictors. The models were extended to allow the scatter around the outcome variable to depend on age, and age-dependent spline functions were incorporated into the models to provide a smooth fit over the entire age range. Mean values and lower limits of normal, defined as the lower 5th percentiles, were derived. RESULT This modelling approach resulted in unbiased estimates of the spirometric outcomes, and the obtained estimates were appropriate not only for the northern Sweden sample but also for the south-western Sweden sample. On average, the GLI reference values for forced expiratory volume in one second (FEV1) and, in particular, forced expiratory vital capacity (FVC) were lower than both the observed values and the new reference values, but higher for the FEV1/FVC ratio. CONCLUSION The evaluation based on the sample of healthy non-smokers from northern Sweden show that the Obstructive Lung Disease in Northern Sweden reference values are valid. Furthermore, the evaluation based on the south-western Sweden sample indicates a high external validity. The comparison with GLI brought further evidence to the consensus that, when available, appropriate local population-specific reference values may be preferred.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Restrictive spirometric pattern in the general adult population: Methods of defining the condition and consequences on prevalence.

BACKGROUND Attempts have been made to use dynamic spirometry to define restrictive lung function, but the definition of a restrictive spirometric pattern (RSP) varies between studies such as BOLD and NHANES. The aim of this study was to estimate the prevalence and risk factors of RSP among adults in northern Sweden based on different definitions. METHODS In 2008-2009 a general population samp...

متن کامل

Evaluation of Superiority of FEV1/VC Over FEV1/FVC for Classification of Pulmonary Disorders

Introduction: Forced expiratory value in one score  (FEV1)/ Forced vital capacity (FVC) was used in classical literature for primary classifications of pulmonary disorders. American Thoracic Society/ European Respiratory Society guidelines recommended using FEV1/VC instead of FEV1/FVC.The aim of study was determination of the extent of superiority of FEV1/VC over the FEV1/FVC. Materials and Met...

متن کامل

Only severe COPD is associated with being underweight: results from a population survey

Low body mass index (BMI) and malnutrition in chronic obstructive pulmonary disease (COPD) are associated with a poor prognosis. The prevalence of underweight, as well as overweight, in severity grades of COPD is sparsely investigated in studies of the general population and the associated patterns of risk factors are not well established. The aim of the present study was to determine the assoc...

متن کامل

GOLD criteria overestimate airflow limitation in one-third of cases in the general Finnish population

The Global Initiative for Chronic Obstructive Lung Disease (GOLD) diagnostic criteria for chronic obstructive pulmonary disease (COPD) use a fixed threshold of forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) ratio (<0.70) in post-bronchodilation spirometry to indicate disease, which has been shown to underestimate and overestimate disease prevalence in younger and older adult...

متن کامل

Transfer factor, lung volumes, resistance and ventilation distribution in healthy adults.

Monitoring of chronic lung disease requires reference values of lung function indices, including putative markers of small airway function, spanning a wide age range.We measured spirometry, transfer factor of the lung for carbon monoxide (TLCO), static lung volume, resistance and ventilation distribution in a healthy population, studying at least 20 subjects per sex and per decade between the a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015