Intraocular pressure measurements with Goldmann applanation tonometry and dynamic contour tonometry in eyes after IntraLASIK or LASEK
نویسندگان
چکیده
BACKGROUND AND METHODS Myopic photorefractive surgery induces a reduction in central corneal thickness, which may lead to underestimation of intraocular pressure. This retrospective clinical study compared intraocular pressure measurements obtained by Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT-Pascal) in eyes undergoing myopic intralaser-assisted in situ keratomileusis (IntraLASIK) or laser-assisted subepithelial keratomileusis (LASEK). RESULTS Of a total of 51 eyes, 21 underwent LASEK and 30 underwent IntraLASIK. By GAT, mean preoperative intraocular pressure was 16.2 ± 1.99 mmHg and postoperatively was 10.84 ± 1.45 mmHg. By DCT, mean preoperative intraocular pressure was 15.9 ± 2.08 mmHg and postoperatively was 16.1 ± 2.3 mmHg. Both preoperative and postoperative differences between measurements made by GAT and DCT were found to be statistically significant (P < 0.04 and P < 0.01, respectively). GAT and DCT readings were unaffected by type of surgery (P = 0.74 and P = 0.46, respectively). CONCLUSION Postoperative GAT measurements were lower than those obtained by DCT. The difference between preoperative and postoperative DCT measurements was minimal, so DCT may be preferable for the measurement of intraocular pressure in eyes undergoing myopic IntraLASIK or LASEK.
منابع مشابه
Correlation between diurnal variation of intraocular pressure, ocular pulse amplitude and corneal structural properties.
PURPOSE The purpose of this study was to evaluate the fluctuation of intraocular pressure measurements obtained by Goldmann applanation tonometry, dynamic contour tonometry, and corneal compensated non-contact tonometry during office hours in glaucoma and healthy participants. This study also aims at correlating the intraocular pressure fluctuations with fluctuations of corneal hysteresis, cent...
متن کاملDynamic Contour Tonometry, Tono-Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral Intraocular Pressure (IOP) Measurements in Patients with Corneal Pathologies
Unspecified Posted at the Zurich Open Repository and Archive, University of Zurich ZORA URL: http://doi.org/10.5167/uzh-101903 Published Version Originally published at: Neuburger, M; Grosswendt, J; Lautebach, S; Maier, P; Birnbaum, F; Böhringer, D; Funk, J; Jordan, J F; Reinhard, T (2014). Dynamic Contour Tonometry, Tono-Pen XL®, and Goldmann Applanation Tonometry in Comparison to Intracameral...
متن کاملEvaluation of Goldmann applanation tonometry, rebound tonometry and dynamic contour tonometry in keratoconus
PURPOSE To compare the intraocular pressure (IOP) measurements obtained with the rebound tonometry (RT), dynamic contour tonometry (DCT) and Goldmann applanation tonometry (GAT) in keratoconic corneas and to investigate the effects of central corneal thickness (CCT) and corneal radius of curvature (CR) on IOP measurements. METHODS Sixty-three eyes of 63 keratoconus patients were enrolled in t...
متن کاملComparison of intraocular pressure measurement between rebound, non-contact and Goldmann applanation tonometry in treated glaucoma patients.
BACKGROUND To compare the intraocular pressure readings obtained with the iCare rebound tonometer and the 7CR non-contact tonometer with those measured by Goldmann applanation tonometry in treated glaucoma patients. DESIGN A prospective, cross-sectional study was conducted in a private tertiary glaucoma clinic. PARTICIPANTS OR SAMPLES One hundred nine (54 males : 55 females) patients includ...
متن کاملClinical comparison of contour and applanation tonometry and their relationship to pachymetry.
OBJECTIVES To compare intraocular pressure readings of recently introduced dynamic contour tonometry (DCT) with pneumatonometry (PTG) and Goldmann applanation tonometry (GAT) and to correlate central corneal thickness (CCT) with these readings. DESIGN Prospective, cross-sectional observation and instrument validation study. We included 258 independent eyes with normal anterior segment examina...