Two-dimensional gas-phase separations coupled to mass spectrometry for analysis of complex mixtures.

نویسندگان

  • Keqi Tang
  • Fumin Li
  • Alexandre A Shvartsburg
  • Eric F Strittmatter
  • Richard D Smith
چکیده

Ion mobility spectrometry (IMS) has been explored for decades, and its versatility in separation and identification of gas-phase ions is well established. Recently, field asymmetric waveform IMS (FAIMS) has been gaining acceptance in similar applications. Coupled to mass spectrometry (MS), both IMS and FAIMS have shown the potential for broad utility in proteomics and other biological analyses. A major attraction of these separations is extremely high speed, exceeding that of condensed-phase alternatives by orders of magnitude. However, modest separation peak capacities have limited the utility of FAIMS and IMS for analyses of complex mixtures. We report 2-D gas-phase separations that join FAIMS to IMS, in conjunction with high-resolution and accuracy time-of-flight (TOF) MS. Implementation of FAIMS/IMS and IMS/MS interfaces using electrodynamic ion funnels greatly improves sensitivity. Evaluation of FAIMS/IMS/TOF performance for a protein mixture tryptic digest reveals high orthogonality between FAIMS and IMS dimensions and, hence, the benefit of FAIMS filtering prior to IMS/MS. The effective peak capacities in analyses of tryptic peptides are approximately 500 for FAIMS/IMS separations and approximately 10(6) for 3-D FAIMS/IMS/MS, providing a potential platform for ultrahigh-throughput analyses of complex mixtures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accessible proteomics space and its implications for peak capacity for zero-, one- and two-dimensional separations coupled with FT-ICR and TOF mass spectrometry.

The number and wide dynamic range of components found in biological matrixes present several challenges for global proteomics. In this perspective, we will examine the potential of zero-dimensional (0D), one-dimensional (1D), and two-dimensional (2D) separations coupled with Fourier-transform ion cyclotron resonance (FT-ICR) and time-of-flight (TOF) mass spectrometry (MS) for the analysis of co...

متن کامل

Overtone mobility spectrometry: part 4. OMS-OMS analyses of complex mixtures.

A new, two-dimensional overtone mobility spectrometry (OMS-OMS) instrument is described for the analysis of complex peptide mixtures. OMS separations are based on the differences in mobilities of ions in the gas phase. The method utilizes multiple drift regions with modulated drift fields such that only ions with appropriate mobilities are transmitted to the detector. Here we describe a hybrid ...

متن کامل

Two-dimensional mapping using different chromatographic separations coupled with mass spectrometry for the analysis of ginsenosides in Panax ginseng root and callus.

Two-dimensional (2D) mapping using different chromatographic separations coupled with mass spectrometry is a rapid and simple method for the analysis of a mixture using conventional liquid chromatography mass spectrometry. The 2D map could be created from two different chromatograms obtained with the same detector and different columns or separation methods. In this study, 2D mapping was applie...

متن کامل

A Multidimensional Lipidomics Method: HILIC Coupled with Ion Mobility Enable Time-of-Flight Mass Spectrometry

K E Y W O R D S Lipids, lipidome, metabolomics, lipidomics, ion mobility spectrometry, Hydrophilic interaction chromatography (HILIC), HDMS Compare, T-WaveTM Technology A P P L I C AT IO N B E N E F I T S Combining HILIC-UPLC liquid phase separation with gas phase ion mobility mass spectrometry to achieve a multi-dimensional characterization of lipids in complex mixtures enhances profiling of l...

متن کامل

SHORT COMMUNICATION Gas-Phase Separations of Protease Digests

A mixture of peptides from a complete tryptic digest of ubiquitin has been analyzed by ion mobility/time-of-flight mass spectrometry techniques. All components of the mixture were electrosprayed and ions were separated in the gas phase based on differences in their mobilities through helium before being dispersed into a time-of-flight mass spectrometer for mass-to-charge analysis. The data show...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical chemistry

دوره 77 19  شماره 

صفحات  -

تاریخ انتشار 2005