Minimally invasive plate osteosynthesis for tibial plateau fractures.

نویسندگان

  • Hasnain Raza
  • Pervaiz Hashmi
  • Kashif Abbas
  • Kamran Hafeez
چکیده

PURPOSE To evaluate radiological and clinical outcome of minimally invasive plate osteosynthesis (MIPO) for tibial plateau fractures. METHODS 35 men and 6 women aged 19 to 75 (mean, 40; standard deviation [SD], 14) years underwent MIPO for displaced tibial plateau fractures. According to the Schatzker system, the tibial plateau fractures were classified as types I (n=3), II (n=9), III (n=11), IV (n=6), V (n=7), and VI (n=5). Six patients had open fractures; 2 of them underwent debridement before MIPO. 10 patients needed additional bone grafting. Radiological (at immediate postoperation) and clinical (at the 12-month follow-up) assessments based on the Rasmussen anatomic and functional scoring system were recorded using a proforma. Patients with acceptable and unacceptable outcomes were compared in terms of age. RESULTS The mean Rasmussen anatomic score was 15.1 (SD, 2.2; range, 10-18); the mean Rasmussen functional score was 25.3 (SD, 3.2; range, 14-29); and the mean range of knee motion was 118 (SD, 10; range, 90-140) degrees. Anatomic outcome was excellent in 10, good in 28, and unacceptable in 3 patients (one each had Schatzker type-I, -II, and -III fractures). 27 (71%) of the 38 patients with acceptable anatomic outcome were aged 45 years or younger, whereas 2 (67%) of the 3 patients with unacceptable anatomic outcome were aged 60 years or older (p=0.001). Functional outcome was excellent in 18, good in 19, and unacceptable in 4 patients (2 had Schatzker type-III and another 2 had Schatzker type-I or -II fractures). 37 of the patients had a range of knee motion of 120 degrees or more; 27 (73%) of them were aged 45 years or younger, whereas 3 (75%) of the 4 patients with unacceptable functional outcome were aged 60 years or older (p=0.001). CONCLUSION MIPO for tibial plateau fractures achieved good outcome with minimal soft-tissue complications. Older age was the predictor of unacceptable outcome.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effectiveness of Minimally Invasive Plate Osteosynthesis (MIPO) on Comminuted Tibial or Femoral Fractures

Background: Comminuted fractures happen frequently due to traumas. Fixation without opening the fracture site,known as minimally invasive plate osteosynthesis (MIPO), has recently become prevalent. This study has beendesigned to assess the outcomes of this treatment for tibial and femoral comminuted fractures.Methods: A total of 60 patients with comminuted femoral or tibial fractures were opera...

متن کامل

A case report of Schatzker type VI tibial plateau fracture treated with double reverse traction closed reduction combined with minimally invasive percutaneous plate osteosynthesis technique

RATIONALE The knee joint is an important weight-bearing joint, tibial plateau fractures affect knee function and stability. High-energy intra-articular fractures involving the tibial plateau can cause management-related problems such as wound dehiscence; severe comminution leading to malalignment; and delayed complications such as varus collapse, implant failure, and arthritis of the knee joint...

متن کامل

Minimally invasive plate osteosynthesis in distal tibial fractures: pitfalls and surgical guidelines.

Distal and tibial pilon fractures often are difficult to treat due to soft-tissue damage from high-energy trauma. Classical surgical treatment may produce additional trauma, eg, periosteal stripping and microcirculatory damage, which frequently induce infection, nonunion, or both. This article presents minimally invasive plate osteosynthesis as a treatment method for these types of fractures. M...

متن کامل

Therapeutic effects of early and delayed minimally invasive percutaneous plate osteosynthesis surgery on distal tibial metaphyseal comminuted fracture

This study aims to investigate the effect of early and delayed injury minimally invasive percutaneous plate osteosynthesis on the treatment of distal tibial metaphyseal comminuted fracture. This study involved 90 patients with distal tibial metaphyseal comminuted fractures for treatment of minimally invasive percutaneous plate osteosynthesis between February 2012 and October 2014 in our hospita...

متن کامل

Comparative study of intramedullary interlocking nailing and minimally invasive percutaneous plate osteosynthesis (MIPO) in extra articular distal tibial fracture

Introduction: Tibia is one of the most commonly fractured long bone of the body. Distal tibia fractures are primarily located within a square based on the width of the distal tibia. Treatment of distal tibia fracture is challenging because of its unique anatomical characteristics of subcutaneous location with precarious blood supply and proximity to the ankle joint. Minimally invasive plate ost...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of orthopaedic surgery

دوره 20 1  شماره 

صفحات  -

تاریخ انتشار 2012