A study of the irradiation temperature coefficient for L-alanine and DL-alanine dosemeters.

نویسندگان

  • Marc F Desrosiers
  • Min Lin
  • Sarenée L Cooper
  • Ying Cui
  • Kesheng Chen
چکیده

Alanine dosimetry is now well established both as a reference and routine dosemeter for industrial irradiation processing. Accurate dosimetry under the relatively harsh conditions of industrial processing requires a characterisation of the parameters that influence the dosemeter response. The temperature of the dosemeter during irradiation is a difficult quantity to measure so that the accuracy of the temperature coefficient that governs the dosemeter response becomes a critical factor. Numerous publications have reported temperature coefficients for several types of alanine dosemeters. The observed differences in the measured values were commonly attributed to the differences in the polymer binder or the experimental design of the measurement. However, the data demonstrated a consistent difference in the temperature coefficients between l-alanine and dl-alanine. Since there were no commonalities in the dosemeter composition or the measurement methods applied, a clear conclusion is not possible. To resolve this issue, the two isomeric forms of alanine dosemeters were prepared and irradiated in an identical manner. The results indicated that the dl-alanine temperature coefficient is more than 50% higher than the l-alanine temperature coefficient.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Convenient method for synthesis of a carbon-14 analogue of DL-Phenyl alanine

DL-Phenyl alanine labeled with carbon-14 in the α-position has been synthesized from ethyl[2-14C] acetate as part of a 6-step sequence.

متن کامل

A Comparison of Harwell & FWT Alanine Temperature Coefficients from 25 °C to 80 °C

The dosimeters used to monitor industrial irradiation processing commonly experience significant temperature rises that must be considered in the dose analysis stage. The irradiation-temperature coefficient for a dosimetry system is derived from the dosimeter's radiation response to the absorbed dose and the irradiation temperature. This temperature coefficient is typically expressed in percent...

متن کامل

Thermodynamic Study of L-alanine in Aqueous Solutions of 1-Hexyl-3-Methylimidazolium Ibuprofenate as an Active Pharmaceutical Ingredient Ionic Liquid (API-IL)

The present work reported density, viscosity, speed of sound, electrical conductivity and refractive index data of L-alanine in the aqueous solutions of 1-hexyl-3-methylimidazolium ibuprofenate at T= 298.15 K. Using the measured data, partial molar volume of transfer ( ), partial molar isentropic compressibility of transfer ( ), viscosity B-coefficient of transfer (∆traB), ion association const...

متن کامل

A study of the alanine dosimeter irradiation temperature coefficient from 25 to 80°C

The response of high-dose-range chemical dosimeters is dependent on the dosimeter temperature during irradiation. Typically, irradiation temperatures are estimated by measurements, calculations, or some combination of the two. Then using the temperature coefficient for the dosimetry system, the dosimeter response is adjusted or corrected to be consistent with the irradiation temperature for the...

متن کامل

Thermodynamic study of interaction between some transition metal ions and L-Alanine

Using UV-vis spectrophotometic method, the formation constants for interaction of Cd2+(aq) andCo2+(aq) ions with L-Alanine were experimentally studied at pH = 4.1 ± 0.01 (50mM of potassiumhydrogen phthalate buffer), ionic strength of 0.1M potassium nitrate and at 5 differenttemperatures 15,20, 25,30 and 35°C. The optical absorption spectra of mixtures containingconsidered cations and L-Alanine ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Radiation protection dosimetry

دوره 120 1-4  شماره 

صفحات  -

تاریخ انتشار 2006