A method for removing imaging artifact from continuous EEG recorded during functional MRI.
نویسندگان
چکیده
Combined EEG/fMRI recording has been used to localize the generators of EEG events and to identify subject state in cognitive studies and is of increasing interest. However, the large EEG artifacts induced during fMRI have precluded simultaneous EEG and fMRI recording, restricting study design. Removing this artifact is difficult, as it normally exceeds EEG significantly and contains components in the EEG frequency range. We have developed a recording system and an artifact reduction method that reduce this artifact effectively. The recording system has large dynamic range to capture both low-amplitude EEG and large imaging artifact without distortion (resolution 2 microV, range 33.3 mV), 5-kHz sampling, and low-pass filtering prior to the main gain stage. Imaging artifact is reduced by subtracting an averaged artifact waveform, followed by adaptive noise cancellation to reduce any residual artifact. This method was validated in recordings from five subjects using periodic and continuous fMRI sequences. Spectral analysis revealed differences of only 10 to 18% between EEG recorded in the scanner without fMRI and the corrected EEG. Ninety-nine percent of spike waves (median 74 microV) added to the recordings were identified in the corrected EEG compared to 12% in the uncorrected EEG. The median noise after artifact reduction was 8 microV. All these measures indicate that most of the artifact was removed, with minimal EEG distortion. Using this recording system and artifact reduction method, we have demonstrated that simultaneous EEG/fMRI studies are for the first time possible, extending the scope of EEG/fMRI studies considerably.
منابع مشابه
Complete artifact removal for EEG recorded during continuous fMRI using independent component analysis.
The simultaneous recording of EEG and fMRI is a promising method for combining the electrophysiological and hemodynamic information on cerebral dynamics. However, EEG recordings performed in the MRI scanner are contaminated by imaging, ballistocardiographic (BCG) and ocular artifacts. A number of processing techniques for the cancellation of fMRI environment disturbances exist: the most popular...
متن کاملDevelopment, validation, and comparison of ICA-based gradient artifact reduction algorithms for simultaneous EEG-spiral in/out and echo-planar fMRI recordings
EEG data acquired in an MRI scanner are heavily contaminated by gradient artifacts that can significantly compromise signal quality. We developed two new methods based on independent component analysis (ICA) for reducing gradient artifacts from spiral in-out and echo-planar pulse sequences at 3 T, and compared our algorithms with four other commonly used methods: average artifact subtraction (A...
متن کاملImplementing a Smart Method to Eliminate Artifacts of Vital Signals
Background: Electroencephalography (EEG) has vital and significant applications in different medical fields and is used for the primary evaluation of neurological disorders. Hence, having easy access to suitable and useful signal is very important. Artifacts are undesirable confusions which are generally originated from inevitable human activities such as heartbeat, blinking of eyes and facial ...
متن کاملICA-based procedures for removing ballistocardiogram artifacts from EEG data acquired in the MRI scanner.
Electroencephalogram (EEG) data acquired in the MRI scanner contains significant artifacts, one of the most prominent of which is ballistocardiogram (BCG) artifact. BCG artifacts are generated by movement of EEG electrodes inside the magnetic field due to pulsatile changes in blood flow tied to the cardiac cycle. Independent Component Analysis (ICA) is a statistical algorithm that is useful for...
متن کاملPii: S1388-2457(00)00456-9
Objective: Electroencephalography (EEG) is a challenge to record simultaneously with functional MRI (fMRI), for it is prone to large artifacts induced by both the static and the time-variant ®elds of the MR scanner. However, truly concurrent EEG/fMRI recording has great potential for clinical and scienti®c neurological applications. We have devised a method for acquiring EEG simultaneously with...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- NeuroImage
دوره 12 2 شماره
صفحات -
تاریخ انتشار 2000