Crestal bone changes around titanium implants: a methodologic study comparing linear radiographic with histometric measurements.

نویسندگان

  • J S Hermann
  • J D Schoolfield
  • P V Nummikoski
  • D Buser
  • R K Schenk
  • D L Cochran
چکیده

Generally, endosseous implants can be placed according to a nonsubmerged or a submerged technique and in 1-piece or 2-piece configurations. Recently, it has been shown that peri-implant crestal bone reactions differ significantly radiographically as well as histometrically under such conditions and are dependent on a rough/smooth implant border in 1-piece implants and on the location of a microgap (interface) between the implant and the abutment/restoration in 2-piece configurations. The purpose of this study was to evaluate whether standardized radiography as a noninvasive clinical diagnostic method correlates with peri-implant crestal bone levels as determined by histometric analysis. Fifty-nine implants were placed in edentulous mandibular areas of 5 foxhounds in a side-by-side comparison in both submerged and nonsubmerged techniques. Three months after implant placement, abutment connection was performed in the submerged implant sites. At 6 months, all animals were sacrificed, and evaluations of the first bone-to-implant contact (fBIC), determined on standardized periapical radiographs, were compared to similar analyses made from nondecalcified histology. It was shown that both techniques provide the same information (Pearson correlation coefficient = 0.993; P < .001). The precision of the radiographs was within 0.1 mm of the histometry in 73.4% of the evaluations, while the level of agreement fell to between 0.1 and 0.2 mm in 15.9% of the cases. These data demonstrate in an experimental study that standardized periapical radiography can evaluate crestal bone levels around implants clinically accurately (within 0.2 mm) in a high percentage (89%) of cases. These findings are significant because crestal bone levels can be determined using a noninvasive technique, and block sectioning or sacrifice of the animal subject is not required. In addition, longitudinal evaluations can be made accurately such that bone changes over various time periods can be assessed. Such analyses may prove beneficial when trying to distinguish physiologic changes from pathologic changes or when trying to determine causes and effects of bone changes around dental implants.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiographic Comparison of Crestal Bone Loss Around Two Implant Systems with Different Surface Roughness: A Retrospective Study

Background and Aim: This retrospective study aimed to investigate the effects of surface roughness and implant body design on the amount of crestal bone loss around implant. Materials and Methods: In this retrospective study, dental records of 87 patients who received 139 implants were evaluated. The ITI group received 63 implants with moderate roughness, while the DIO group received 76 implan...

متن کامل

Radiographic Evaluation of Marginal Bone Loss Following Immediate and Delayed Implantation

Background and Aim: Intraosseous implants can be placed using three different techniques: immediate, early, and delayed. The aim of this study was to compare the changes in the marginal bone level around implants after immediate and delayed im-plant placement. Materials and Methods: In the present prospective cohort study, 26 implants were placed in 26 patients divided into two groups. In grou...

متن کامل

Changes in crestal bone around endosseous implants during functional loading: a radiographic evaluation in edentulous patients comparing different implant designs.

Marginal bone changes around titanium plasma-sprayed implants (n = 240) placed in the mandibular interforaminal regions of 120 edentulous patients were assessed over 5 years of follow-up, with emphasis on the influence of the locations of the microgap and rough/smooth border. Marginal bone changes were measured on standardized radiographs. Locations of the microgap and the rough/smooth border w...

متن کامل

بررسی رادیوگرافیک اثر بارگذاری تدریجی بر روی تغییرات استخوان کرستال و تراکم استخوان اطراف ایمپلنت‌های تک واحدی خلف ماگزیلا

Background and Aim: The aim of this clinical study was to determine the effectiveness of progressive loading procedures on preserving crestal bone height and improving peri-implant bone density around maxillary implants restored with single crowns by an accurate longitudinal radiographic assessment technique. Materials and Methods: Eleven Micro-Thread Osseo Speed dental implants were place...

متن کامل

Crestal Bone Loss Around Dental Implants; A Short Communication

Many studies described several parameters which are supposed to determine success or failure in longterm evaluations of dental implants. However, the relationship between crestal bone loss around implants and the location of implant-abutment connection in the bone still needs further investigations.The subgingival microgap between the implant and the abutment, which creates higher bone level re...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The International journal of oral & maxillofacial implants

دوره 16 4  شماره 

صفحات  -

تاریخ انتشار 2001