Electroacoustic verification of frequency modulation systems in cochlear implant users.
نویسندگان
چکیده
INTRODUCTION The frequency modulation system is a device that helps to improve speech perception in noise and is considered the most beneficial approach to improve speech recognition in noise in cochlear implant users. According to guidelines, there is a need to perform a check before fitting the frequency modulation system. Although there are recommendations regarding the behavioral tests that should be performed at the fitting of the frequency modulation system to cochlear implant users, there are no published recommendations regarding the electroacoustic test that should be performed. OBJECTIVE Perform and determine the validity of an electroacoustic verification test for frequency modulation systems coupled to different cochlear implant speech processors. METHODS The sample included 40 participants between 5 and 18 year's users of four different models of speech processors. For the electroacoustic evaluation, we used the Audioscan Verifit device with the HA-1 coupler and the listening check devices corresponding to each speech processor model. In cases where the transparency was not achieved, a modification was made in the frequency modulation gain adjustment and we used the Brazilian version of the "Phrases in Noise Test" to evaluate the speech perception in competitive noise. RESULTS It was observed that there was transparency between the frequency modulation system and the cochlear implant in 85% of the participants evaluated. After adjusting the gain of the frequency modulation receiver in the other participants, the devices showed transparency when the electroacoustic verification test was repeated. It was also observed that patients demonstrated better performance in speech perception in noise after a new adjustment, that is, in these cases; the electroacoustic transparency caused behavioral transparency. CONCLUSION The electroacoustic evaluation protocol suggested was effective in evaluation of transparency between the frequency modulation system and the cochlear implant. Performing the adjustment of the speech processor and the frequency modulation system gain are essential when fitting this device.
منابع مشابه
EFFECT OF A UDITORY-VERBAL REHABILITATION ON VOICE PARAMETERS IN CHILD COCHLEAR IMPLANT USERS
This study aimed to evaluate the effects of auditory-verbal rehabilitation on voice parameters after implantation with cochlear implants 2 and 5 months after rehabilitation and compare them with normal voice children (under 12 years of age). A perceptive and electroacoustic evaluation of voice was carried out through a digital analysis after implantation and rehabilitation. The study was pe...
متن کاملInterfacing FM Systems with Implantable Hearing Devices
Cochlear implant recipients can reduce the challenges they encounter in noisy environments through the use of a remote microphone. Although there are numerous options for delivering the signal from the frequency modulated (FM) transmitter worn by the speaker to the FM receiver coupled to the implant, several have now been verified through research as viable, beneficial arrangements. Recommendat...
متن کاملEFFECT OF A UDITORY-VERBAL REHABILITATION ON VOICE PARAMETERS IN CHILD COCHLEAR IMPLANT USERS
This study aimed to evaluate the effects of auditory-verbal rehabilitation on voice parameters after implantation with cochlear implants 2 and 5 months after rehabilitation and compare them with normal voice children (under 12 years of age). A perceptive and electroacoustic evaluation of voice was carried out through a digital analysis after implantation and rehabilitation. The study was pe...
متن کاملBimodal hearing benefit for speech recognition with competing voice in cochlear implant subject with normal hearing in contralateral ear.
OBJECTIVES This project assessed electroacoustic benefit for speech recognition with a competing talker. DESIGN Using a cochlear implant subject with normal hearing in the contralateral ear, the contribution of low-pass and high-pass natural sound to speech recognition was systematically measured. RESULTS High-frequency sound did not improve performance, but low-frequency sound did, even wh...
متن کاملModulation rate discrimination using half-wave rectified and sinusoidally amplitude modulated stimuli in cochlear-implant users.
Detection and modulation rate discrimination were measured in cochlear-implant users for pulse-trains that were either sinusoidally amplitude modulated or were modulated with half-wave rectified sinusoids, which in acoustic hearing have been used to simulate the response to low-frequency temporal fine structure. In contrast to comparable results from acoustic hearing, modulation rate discrimina...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Brazilian journal of otorhinolaryngology
دوره شماره
صفحات -
تاریخ انتشار 2017