Development of an automatic evaluation method for patient positioning error

نویسندگان

  • Yoshiki Kubota
  • Mutsumi Tashiro
  • Ayaka Shinohara
  • Satoshi Abe
  • Saki Souda
  • Ryosuke Okada
  • Takayoshi Ishii
  • Tatsuaki Kanai
  • Tatsuya Ohno
  • Takashi Nakano
چکیده

Highly accurate radiotherapy needs highly accurate patient positioning. At our facility, patient positioning is manually performed by radiology technicians. After the positioning, positioning error is measured by manually comparing some positions on a digital radiography image (DR) to the corresponding positions on a digitally reconstructed radiography image (DRR). This method is prone to error and can be time-consuming because of its manual nature. Therefore, we propose an automated measuring method for positioning error to improve patient throughput and achieve higher reliability. The error between a position on the DR and a position on the DRR was calculated to determine the best matched position using the block-matching method. The zero-mean normalized cross correlation was used as our evaluation function, and the Gaussian weight function was used to increase importance as the pixel position approached the isocenter. The accuracy of the calculation method was evaluated using pelvic phantom images, and the method's effectiveness was evaluated on images of prostate cancer patients before the positioning, comparing them with the results of radiology technicians' measurements. The root mean square error (RMSE) of the calculation method for the pelvic phantom was 0.23 ± 0.05 mm. The coefficients between the calculation method and the measurement results of the technicians were 0.989 for the phantom images and 0.980 for the patient images. The RMSE of the total evaluation results of positioning for prostate cancer patients using the calculation method was 0.32 ± 0.18 mm. Using the proposed method, we successfully measured residual positioning errors. The accuracy and effectiveness of the method was evaluated for pelvic phantom images and images of prostate cancer patients. In the future, positioning for cancer patients at other sites will be evaluated using the calculation method. Consequently, we expect an improvement in treatment throughput for these other sites.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Image quality enhancement in digital panoramic radiograph

One of the most common positioning errors in panoramic radiography is palatoglossal air space above the apices of the root of maxillary teeth. It causes a radiolucency obscuring the apices of maxillary teeth. In the case of this positioning error, the imaging should be repeated. This causes the patient be exposed to radiation again. To avoid the repetition of exposing harmful X-rays to the pati...

متن کامل

Common Positioning Errors in Digital Panoramic Radiographies Taken In Mashhad Dental School

Introduction: The present study was aimed at evaluating common positioning errors on panoramic radiographs taken in the Radiology Department of Mashhad Dental School. Materials and methods: The study sample included 1,990 digital panoramic radiographs taken in the Radiology Department of Mashhad Dental School by a Planmeca Promax (Planmeca Oy, Helsinki, Finland), during a 2-year period (2010–20...

متن کامل

Investigation on the Effect of Different Parameters in Wheeled Mobile Robot Error (TECHNICAL NOTE)

This article has focused on evaluation and identification of effective parameters in positioning performance with an odometry approach of an omni-directional mobile robot. Although there has been research in this field, but in this paper, a new approach has been proposed for mobile robot in positioning performance. With respect to experimental investigations of different parameters in omni-dire...

متن کامل

Improvement and Evaluation of a Time-of-Flight-based Patient Positioning System

In this paper we improve a surface-based patient positioning method. The method describes a system for automatic positioning of patients using time-of-flight cameras in radiotherapy. To improve the registration result three new preprocessing steps (bilateral filtering, temporal averaging, variance filtering) are introduced to the processing pipeline. Furthermore, the accuracy of the surface mat...

متن کامل

An Evaluation of Infrastructure-free and Infrastructure-based Indoor Positioning Methods with the Focus on Pedestrian Dead Reckoning

The expansion of location-based services (LBS) and their applications has led to a growing interest in localization, which can be done on the smartphone platform. Various positioning techniques can be used for indoor or outdoor positioning. Indoor positioning systems have been one of the most challenging technologies in location-based services over the past decade. Considering the increase of p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015