Evaluation of two foot-to-foot bioelectrical impedance analysers to assess body composition in overweight and obese adolescents.

نویسندگان

  • Stefano Lazzer
  • Yves Boirie
  • Martine Meyer
  • Michel Vermorel
چکیده

The objective of the present study was to determine the accuracy of two foot-to-foot (FF) bioelectrical impedance analysers (BIA) to assess body composition in overweight and obese adolescents, compared with dual-energy X-ray absorptiometry (DXA) and hand-to-foot (HF) BIA. Body composition was assessed in fifty-three overweight or obese adolescents (BMI 27.9 (SD 4.1) kg/m2; aged 13-16 years) by DXA (Hologic QDR-4500; Hologic Inc., Bedford, MA, USA) and BIA (HF (BIA 101, RJL System, Detroit, IL, USA) and FF (Body Fat Monitor Scale BF-625, Tanita Corporation of America Inc., Arlington Heights, IL, USA; Téfal Bodymaster Vision, Téfal, Rumilly, France)). Bland-Altman tests showed that, compared with DXA, FF-Tanita and FF-Téfal underestimated (P<0.05) fat mass (FM) less than HF-BIA (-1.7 (SD 3.1), -0.7 (SD 5.8) and -2.3 (SD 2.2) kg respectively, P<0.001). However, the limits of agreement between DXA and FF-Tanita or FF-Téfal were much greater than those obtained with HF-BIA (-7.7 and +4.3, - 12.0 and +10.6 v. -2.1 and +6.7 kg respectively). The differences between FM assessed using the FF-Tanita or the FF-Téfal analyser and DXA increased with the waist:hip ratio, and were higher in boys than in girls. The major limiting factor of FF-BIA was the inter-individual variability in FM estimates. In conclusion, FF-BIA and DXA are not interchangeable methods. FF-BIA could be acceptable to assess body composition in large groups of overweight or obese adolescents, but cannot be recommended for body composition assessment in obese subjects because of the large errors in individual estimates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Muscle Mass, Total Body Water and Total Body Protein in Type II Diabetics with Healthy Matched Adults by Bioelectrical Impedance Analysis

Background: Bioelectrical impedance analysis (BIA) is a new and rapid technique to validate body composition. Several studies have used this technique to evaluate body compositions, such as muscle mass, in diabetic patients, but the results are very different. This may due the differences between diabetic patients and control group. Therefore, this study aimed to compare the muscle mass of diab...

متن کامل

Comparison of different body composition measurements in severely obese patients in the clinical setting.

BACKGROUND AIMS Body composition measurements seem to be not reliable enough in obese patients. Our aim was to compare single frequency-bioelectrical impedance (SF-BIA) analysis; foot-to-foot impedance meters (FFI) or upper body fat analysers (UBFA) and DXA (Dual-energy X-ray absorptiometry) in severely obese patients. PATIENTS AND METHODS Cross-sectional study including 40 severely obese pat...

متن کامل

Body Composition in Healthy Obese/Overweight and Normal Weight Subjects Compared to Patients with Metabolic Syndrome

Background: According to previous studies, patient with metabolic syndrome (MetS) are different in terms of body composition from healthy subjects. The purpose of the present study was to determine the body composition of healthy obese/overweight patients and compared them with those having MetS. Methods: A case-control study was conducted on both men and women aged 20 to 55 years, who were sel...

متن کامل

Accuracy of bioelectrical impedance consumer devices for measurement of body composition in comparison to whole body magnetic resonance imaging and dual X-ray absorptiometry.

OBJECTIVE To compare body composition determined by bioelectrical impedance (BIA) consumer devices against criterion estimates determined by whole body magnetic resonance imaging (MRI) and dual energy X-ray absorptiometry (DXA) in healthy normal weight, overweight and obese adults. METHODS In 106 adults (54 females, 52 males, age 54.2 +/- 16.1 years, BMI 25.8 +/- 4.4 kg/m(2)) fat mass (FM), s...

متن کامل

Bioelectrical impedance analysis to estimate body composition, and change in adiposity, in overweight and obese adolescents: comparison with dual-energy x-ray absorptiometry

BACKGROUND There is a need for a practical, inexpensive method to assess body composition in obese adolescents. This study aimed to 1) compare body composition parameters estimated by a stand-on, multi-frequency bioelectrical impendence (BIA) device, using a) the manufacturers' equations, and b) published and derived equations with body composition measured by dual-energy x-ray absorptiometry (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The British journal of nutrition

دوره 90 5  شماره 

صفحات  -

تاریخ انتشار 2003