Use of the American College of Radiology BI-RADS guidelines by community radiologists: concordance of assessments and recommendations assigned to screening mammograms.
نویسندگان
چکیده
OBJECTIVE This study evaluated the use of the American College of Radiology Breast Imaging Reporting and Data System (BI-RADS) by community radiologists by determining the concordance of assessment categories and recommendations assigned to screening mammograms. MATERIALS AND METHODS The study comprised the interpretations of 82,620 consecutive screening mammograms by 18 radiologists between January 1, 1995, and December 31, 1998. For all mammograms, assessment categories and recommendations were compared to determine whether they were in accordance with BI-RADS guidelines. Overall patterns of discordance were analyzed, and comparisons of discordant patterns by assessment category, patient age, breast density, and year of examination were made. RESULTS The overall discordance between BI-RADS assessments and recommendations was low (3%). The assessment with the highest discordance was "probably benign finding" (category 3), at 53.5%. Mammograms obtained in 1998 were almost half as likely to have assessment-recommendation discordance compared with those obtained in 1995 (2.4% vs 4.5%, respectively; odds ratio = 0.52; p < 0.001). Mammograms of women with dense breast tissue were 30% more likely to have lesions assigned discordant assessments and recommendations compared with those of women with fatty tissue (3.4% vs 2.7%, respectively; odds ratio = 1.3; p < 0.001). No differences in the patterns of discordance were found between mammograms of women younger than 50 years and those of women 50 years old and older (p = 0.10). CONCLUSION There has been improvement in the accurate application of BI-RADS since its introduction. However, variation in the pairing of BI-RADS assessments and recommendations persists. Continued efforts to educate radiologists about the use of BI-RADS and to clarify BI-RADS terms would promote maximum consistency in this use of this reporting method.
منابع مشابه
Automated Indexing of Mammography Reports Using Linear Least Squares Fit
Radiologists routinely document mammography results in free text dictations. In the last decade, there has been an increase in the volume of mammography performed in the U.S. As a result, The American College of Radiology has standardized the practice of screening mammography by introducing a controlled vocabulary and practice standards tracked by audits. Extracting data from these free text re...
متن کاملObjectivity and accuracy of mammogram interpretation using the BI-RADS final assessment categories in 40- to 49-year-old women.
To determine if use of the five final assessment categories of the American College of Radiology's Breast Imaging Reporting and Data System (BI-RADS) improved objectivity or accuracy of mammographic evaluation in 40- to 49-year-old women, fifty mammograms of 40- to 49-year-old women that were obtained at a tertiary referral teaching hospital were classified according to those five final assessm...
متن کاملAssessing an Emerging Nationwide Population-based Mammography Screening Program in Taiwan Huay-Ben Pan1,2,3 Giu-CHenG Hsu4 Huei-LunG LianG1,2 CHen-Pin CHou1,2 yen-CHi WanG1,2 san-Kan Lee5 yi-HonG CHou2,6 Kam-Fai WonG7
Breast cancer is the most common cancer and ranks fourth among cancer deaths in women in Taiwan. In 2004, Taiwan’s Bureau of Health Promotion, Department of Health and Radiology Society of Republic of China collaborated to implement a program to monitor the quality and trained the people involved in a nationwide biennially mammography screening program for women between 50 and 69 years of age, ...
متن کاملObserver Agreement Using the ACR Breast Imaging Reporting and Data System (BI-RADS)-Ultrasound, First Edition (2003)
OBJECTIVE This study aims to evaluate the degree of inter- and intraobserver agreement when characterizing breast abnormalities using the Breast Imaging Reporting and Data System (BI-RADS)-ultrasound (US) lexicon, as defined by the American College of Radiology (ACR). MATERIALS AND METHODS Two hundred ninety three female patients with 314 lesions underwent US-guided biopsies at one facility d...
متن کاملMammographic features and correlation with biopsy findings using 11-gauge stereotactic vacuum-assisted breast biopsy (SVABB).
BACKGROUND Mammograms are assigned a BI-RADS (Breast Imaging Reporting and Data System) category, which indicates the level of suspicion for cancer. OBJECTIVES (i) To evaluate the use of BI-RADS categories in a non-academic radiology practice based in a community hospital compared with local radiology private offices; (ii) to determine positive predictive value (PPV), sensitivity and specific...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJR. American journal of roentgenology
دوره 179 1 شماره
صفحات -
تاریخ انتشار 2002