The diagnosis of gastro-oesophageal reflux (GOR) is of great interest for paediatric gastroenterologists. pH monitoring is the commonly used procedure for GOR diagnosis but a major amount of postprandial GOR is missed due to the mostly non-acidic gastric contents in infants. The multiple intraluminal impedance technique is based on the recording of the impedance changes during bolus transport inside the oesophagus. It is the first method which allows the pH-independent, long-term registration of GOR. The use of the impedance technology in clinical practice has been limited so far by the time-consuming, visual evaluation of the impedance traces. The new approach of a semi-automatic analysis of the impedance measurements allows the automated detection of reflux patterns. It is based on event marking and an optimised feature description of the impedance traces combined with a fuzzy system for pattern recognition. The classifier is developed and tested on 50 investigations in infants. Compared to the comprehensive, multiple visual evaluation the achieved precision is 75% sensitivity and 48% positive prediction. In comparison to a single visual evaluation the analysis of the automatically proposed patterns corresponds to a 96% reduction of the evaluation time with no loss of precision. Thus the applicability of the impedance technology is enhanced significantly. A combined measurement of pH and impedance gives evidence about the occurrence of GOR, its pH and the acidic exposure of the oesophagus.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patterns of gas and liquid reflux during transient lower oesophageal sphincter relaxation: a study using intraluminal electrical impedance.

BACKGROUND Belching has been proposed as a major mechanism underlying acid gastro-oesophageal reflux in normal subjects. However, the presence of oesophageal gas has not been measured directly but only inferred from manometry. AIMS To investigate, using intraluminal electrical impedance, the patterns of gas and liquid reflux during transient lower oesophageal sphincter (LOS) relaxations, the ...

متن کامل

Effect of Gaviscon Infant on gastro-oesophageal reflux in infants assessed by combined intraluminal impedance/pH.

BACKGROUND Gaviscon Infant (GI) has been recommended for gastro-oesophageal reflux (GOR) in infants. Its efficacy has not been examined with a physiologically appropriate denominator to define the degree of GOR. AIM To investigate the influence of Gaviscon Infant on GOR in infants using combined pH and intraluminal impedance measurement. METHODS Twenty infants (mean age 163.5 days, range 34...

متن کامل

Gastro-oesophageal reflux monitoring: review and consensus report on detection and definitions of acid, non-acid, and gas reflux.

To date, most concepts on the frequency of gastro-oesophageal reflux episodes and the efficiency of the antireflux barrier have been based on inferences derived from measurement of oesophageal pH. The development of intraluminal impedance monitoring has highlighted the fact that pH monitoring does not detect all gastro-oesophageal reflux events when little or no acid is present in the refluxate...

متن کامل

CASE REPORT Fundoplication eliminates chronic cough due to non-acid reflux identified by impedance pH monitoring

The symptoms of extra-oesophageal gastro-oesophageal reflux disease (GORD) (such as chronic cough and hoarseness) are traditionally more difficult to treat than typical GORD symptoms (heartburn and regurgitation). Patients with extra-oesophageal manifestations may require longer and higher doses of acid suppressive therapy. In patients not responding to acid suppressive therapy the physician fa...

متن کامل

Minimum sample frequency for multichannel intraluminal impedance measurement of the oesophagus.

In all systems for impedance monitoring signals are stored in digital format after analog-to-digital conversion at a predefined rate, the sample frequency. We aimed to find the minimum sample frequency required to evaluate oesophageal transit and gastro-oesophageal reflux studies using impedance monitoring. In 10 healthy subjects and five patients with gastro-oesophageal reflux disease impedanc...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Medical engineering & physics

دوره 21 3  شماره 

صفحات  -

تاریخ انتشار 1999