A Steam - Boiler Control

نویسنده

  • Matthias Weber
چکیده

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Monitoring and Controlling of Boiler Drum Parameters Using Lab View

The boiler drum level control unit is one of the main parameter in the thermal power station. Currently the boiler drum parameters are monitored only by using MATLAB software. There is no automatic control available. In the proposed system the boiler drum parameters such as temperature level, pressure level, water level and Droplet identifier are measured and controlled by using embedded proces...

متن کامل

Importance of Three-elements Boiler Drum Level Control and Its Installation in Power Plant

Conversion of water into steam is the primary function of a utility boiler. The steam pressure is used to turn a steam turbine thus, generating electricity. Within the boiler drum there exists a steam/water interface. Boiler steam drum water level is one of the important parameters of power plant that must be measured and controlled. For safe and efficient boiler operation, a constant level of ...

متن کامل

Control System Simulator for Steam Boiler Parameters

Abstract: The paper presents the research results related to control of the steam boiler parameters: drum level, furnace pressure and steam pressure. It was developed the mathematical model of the water-steam system and furnace part of the boiler. Also, the paper presents the algorithm for real time detection of model parameter variations. In this context a correction method, validate through s...

متن کامل

The Application of Fuzzy Neural Network to Boiler Steam Pressure Control

The control effect of steam pressure is one of the most important factors influencing stability in chain type boiler. Aimed at the problem that the control of steam pressure is restricted by many factors, a kind of fuzzy neural network (FNN) is presented in this paper. The controller has the advantage of self-adapting, self-learning and tuning on-line. In simulation, this system exerts stably, ...

متن کامل

Boiler Modelling and Optimal Control of Steam Temperature in Thermal Power Plants

Achieving accurate control of main steam temperature is a very difficult task in thermal power plants due to the large process lag (8 to 10 minutes) associated with the superheater system and there exists a deviation of ± 10 °C in closed loop control. A control oriented boiler model and an appropriate optimal control strategy are the essential tools for improving the accuracy of this control sy...

متن کامل

An Algebraic Specification of the Steam-Boiler Control System

In Formal methods for industrial applications: specifying and programming the steam boiler control,

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1996