BACKGROUND Kinematically aligned TKA restores function by aligning the femoral and tibial components to the normal or prearthritic joint lines of the knee. However, aligning the components to the joint lines of the normal knee also aligns the tibial component in varus, creating concern that varus alignment might result in poor function and early catastrophic failure. QUESTIONS/PURPOSES We therefore determined whether function and the incidence of catastrophic failure were different when the tibial component, knee, and limb alignment were in a specified normal range, varus outlier, or valgus outlier. METHODS We prospectively followed all 198 patients (214 knees) who underwent TKAs between February and October 2008. We treated each knee in this cohort of patients with a kinematically aligned, cruciate-retaining prosthesis implanted using patient-specific guides. From a long-leg scanogram, we measured and categorized alignment of the tibial component as in range (≤ 0°) or a varus outlier (> 0°), alignment of the knee as in range (between -2.5° to -7.4° valgus) or a varus (> -2.5°) or valgus (< -7.4°) outlier, and alignment of the limb as in range (0° ± 3°) or a varus (> 3°) or valgus (< -3°) outlier. We assessed function using the Oxford Knee Score and WOMAC score, and reported catastrophic failure as the incidence of revision attributable to loosening, wear, and instability of the femoral or tibial components. The minimum followup was 31 months (mean, 38 months; range, 31-43 months). RESULTS The mean Oxford Knee Score of 43 and WOMAC score of 92 were similar between the three alignment categories. The incidence of catastrophic failure in each alignment category was zero. CONCLUSIONS Kinematically aligned TKA restores function without catastrophic failure regardless of the alignment category. Because 75% of patients had their tibial component categorized as a varus outlier and also had high function and a zero incidence of catastrophic failure, the concern that kinematic alignment compromises function and places the components at a high risk for catastrophic failure is unfounded and should be of interest to surgeons committed to cutting the tibia perpendicular to the mechanical axis of the tibia. LEVEL OF EVIDENCE Level IV, therapeutic study. See Guidelines for Authors for a complete description of levels of evidence.
منابع مشابه
Kinematic alignment produces near-normal knee motion but increases contact stress after total knee arthroplasty: A case study on a single implant design.
BACKGROUND Kinematically aligned total knee arthroplasty (TKA) is of increasing interest because this method might improve postoperative patient satisfaction. In kinematic alignment the femoral component is implanted in a slightly more valgus and internally rotated position, and the tibial component is implanted in a slightly more varus and internally rotated position, than in mechanical alignm...
متن کاملKinematically versus mechanically aligned total knee arthroplasty.
The purpose of this study was to compare 2 alignment methods for total knee arthroplasty (TKA): kinematic alignment with the use of patient-specific guides and mechanical alignment with conventional instruments. A randomized, controlled trial of 41 kinematically aligned and 41 mechanically aligned patients was conducted with the patient, radiographic evaluator, and clinical evaluator blinded to...
متن کاملDoes Kinematic Alignment and Flexion of a Femoral Component Designed for Mechanical Alignment Reduce the Proximal and Lateral Reach of the Trochlea?
BACKGROUND Kinematically aligned total knee arthroplasty uses a femoral component designed for mechanical alignment (MA) and sets the component in more internal, valgus, and flexion rotation than MA. It is unknown how much kinematic alignment (KA) and flexion of the femoral component reduce the proximal and lateral reach of the trochlea; two reductions that could increase the risk of abnormal p...
متن کاملComparison Of Gait Biomechanics Between Kinematically Aligned And Neutrally Aligned Total Knee Arthroplasty
متن کامل
Different References for Valgus Cut Angle in Total Knee Arthroplasty
Background: The valgus cut angle (VCA) of the distal femur in Total Knee Arthroplasty (TKA) is measured preoperativelyon three-joint alignment radiographs. The anatomical axis of the femur can be described as the anatomical axis of thefull length of the femur or as the anatomical axis of the distal half of the femur, which may result in different anglesin some cases. During TKA, the anatomical ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Clinical orthopaedics and related research
دوره 471 3 شماره
صفحات -
تاریخ انتشار 2013