Insertion profiles of 4 headless compression screws.

نویسندگان

  • Adam Hart
  • Edward J Harvey
  • Louis-Philippe Lefebvre
  • Francois Barthelat
  • Reza Rabiei
  • Paul A Martineau
چکیده

PURPOSE In practice, the surgeon must rely on screw position (insertion depth) and tactile feedback from the screwdriver (insertion torque) to gauge compression. In this study, we identified the relationship between interfragmentary compression and these 2 factors. METHODS The Acutrak Standard, Acutrak Mini, Synthes 3.0, and Herbert-Whipple implants were tested using a polyurethane foam scaphoid model. A specialized testing jig simultaneously measured compression force, insertion torque, and insertion depth at half-screw-turn intervals until failure occurred. RESULTS The peak compression occurs at an insertion depth of -3.1 mm, -2.8 mm, 0.9 mm, and 1.5 mm for the Acutrak Mini, Acutrak Standard, Herbert-Whipple, and Synthes screws respectively (insertion depth is positive when the screw is proud above the bone and negative when buried). The compression and insertion torque at a depth of -2 mm were found to be 113 ± 18 N and 0.348 ± 0.052 Nm for the Acutrak Standard, 104 ± 15 N and 0.175 ± 0.008 Nm for the Acutrak Mini, 78 ± 9 N and 0.245 ± 0.006 Nm for the Herbert-Whipple, and 67 ± 2N, 0.233 ± 0.010 Nm for the Synthes headless compression screws. CONCLUSIONS All 4 screws generated a sizable amount of compression (> 60 N) over a wide range of insertion depths. The compression at the commonly recommended insertion depth of -2 mm was not significantly different between screws; thus, implant selection should not be based on compression profile alone. Conically shaped screws (Acutrak) generated their peak compression when they were fully buried in the foam whereas the shanked screws (Synthes and Herbert-Whipple) reached peak compression before they were fully inserted. Because insertion torque correlated poorly with compression, surgeons should avoid using tactile judgment of torque as a proxy for compression. CLINICAL RELEVANCE Knowledge of the insertion profile may improve our understanding of the implants, provide a better basis for comparing screws, and enable the surgeon to optimize compression.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of Five Headless Screws for Fixation of Small Bones

Headless screws are favored for internal fixation in the treatment of displaced or unstable small bone (e.g., Scaphoid) fractures, because they are embedded below the articular surface of the bone, reducing tissue irritation and immobilization. Compression plays an important role in fracture stability, maintaining gap reduction and also accelerating the healing of cancellous bone [1]. There are...

متن کامل

Biomechanical comparison of first metatarsophalangeal joint arthrodeses using triple-threaded headless screws versus partially threaded lag screws.

BACKGROUND Triple-threaded, cannulated headless screws of varying thread diameters and pitch are designed to maintain thread length across the arthrodesis plane, provide joint compression, and reduce countersinking. This study tested the biomechanical fixation strength of conventional partially threaded lag screws compared to triple-threaded headless screws in first metatarsophalangeal joint ar...

متن کامل

Bicondylar Hoffa Fracture Successfully Treated with Headless Compression Screws

Bicondylar coronal plane fracture, eponymically named Hoffa fractures, is an extremely rare injury. We present a case of isolated unilateral bicondylar Hoffa fracture that was successfully treated with open reduction and internal fixation using headless compression screws with satisfactory results. We inserted posteroanteriorly oriented Acutrak screws perpendicular to the fracture plane via lat...

متن کامل

A comparison of two headless compression screws for operative treatment of scaphoid fractures

PURPOSE The purpose of this study was to compare the interfragmentary compression force across a simulated scaphoid fracture by two commonly used compression screw systems; the Acutrak 2 Standard and the 3.0 mm Synthes headless compression screw. METHODS Sixteen (8 pairs; 6 female, 2 male) cadaver scaphoids were randomly assigned to receive either the Acutrak 2 or Synthes screw with the contr...

متن کامل

Early motion following 4-corner arthrodesis using cannulated compression screws: a biomechanical study.

PURPOSE To assess the ability of headless compression screws to maintain immobile bony contact throughout wrist cycling following simulated 4-corner arthrodesis. Our hypothesis was that the screw constructs would not permit displacement of the carpal bones and, therefore, could tolerate early postoperative range of motion in vivo. METHODS Using 6 matched-paired cadaveric arms, 4-corner arthro...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The Journal of hand surgery

دوره 38 9  شماره 

صفحات  -

تاریخ انتشار 2013