The vibration plethysmographic method of arterial compliance analysis in dependence on transmural pressure.

نویسندگان

  • J Moudr
  • J Svačinová
  • E Závodná
  • N Honzíková
چکیده

The aim of this study was to obtain a detailed analysis of the relationship between the finger arterial compliance C [ml/mm Hg] and the arterial transmural pressure P(t) [mm Hg]. We constructed a dynamic plethysmograph enabling us to set up a constant pressure P(css) [mm Hg] and a superimposed fast pressure vibration in the finger cuff (equipped with a source of infra-red light and a photoelectric sensor for the measurement of arterial volume). P(css) could be set on the required time interval in steps ranging between 30 and 170 mm Hg, and on sinusoidal pressure oscillation with an amplitude P(ca) (2 mm Hg) and a frequency f (20, 25, 30, 35, 40 Hz). At the same time continuous blood pressure BP was measured on the adjacent finger (Portapres). We described the volume dependence of a unitary arterial length on the time-varying transmural pressure acting on the arterial wall (externally P(css)+P(ca).sin(2pif), internally BP) by a second-order differential equation for volume. This equation was linearized within a small range of selected BP. In the next step, a Fourier transform was applied to obtain the frequency characteristic in analytic form of a complex linear combination of frequency functions. While series of oscillations [P(ca), f] were applied for each P(css), the corresponding response of the plethysmogram was measured. Amplitude spectra were obtained to estimate coefficients of the frequency characteristic by regression analysis. We determined the absolute value: elastance E, and its inverse value: compliance (C=1/E). Then, C=C(P(t)) was acquired by applying sequences of oscillations for different P(css) (and thus P(t)) by the above-described procedure. This methodology will be used for the study of finger arterial compliance in different physiological and pathological conditions.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه بکارگیری دو روش تمرینات تنفسی غیر فعال دق دستی و ارتعاش مکانیکی بر عملکرد قلبی و ریوی بیماران تحت تهویه مکانیکی در بخش مراقبت‌های ویژه

Introduction & Objective: passive respiratory exercises are used to prevent from accumulation of secretions, lung collapse and the incidence of ventilator-associated pneumonia in ICUs. This  study is aimed to compare the effects of manual percussion and mechanical vibrations on cardiopulmonary functions of mechanically ventilated patients. Materials &Methods: This randomized crossover clinical...

متن کامل

Decreased capillary filtration but maintained venous compliance in the lower limb of aging women.

There are sex-related differences in venous compliance and capillary filtration in the lower limbs, which to some extent can explain the susceptibility to orthostatic intolerance in young women. With age, venous compliance and capacitance are reduced in men. This study was designed to evaluate age-related changes in venous compliance and capillary filtration in the lower limbs of healthy women....

متن کامل

Relation between respiratory variations in pulse oximetry plethysmographic waveform amplitude and arterial pulse pressure in ventilated patients

INTRODUCTION Respiratory variation in arterial pulse pressure is a reliable predictor of fluid responsiveness in mechanically ventilated patients with circulatory failure. The main limitation of this method is that it requires an invasive arterial catheter. Both arterial and pulse oximetry plethysmographic waveforms depend on stroke volume. We conducted a prospective study to evaluate the relat...

متن کامل

Arterial and plethysmographic waveform analysis in anesthetized patients with hypovolemia.

BACKGROUND Respiratory-induced arterial and plethysmographic (pulse oximetry) waveform changes were shown to be good predictors of cardiac output response to increased preload. The aim of this study was to evaluate the reliability of arterial and plethysmographic waveform variables in patients with mild hypovolemia. METHODS Patients undergoing autologous hemodilution were studied. After anest...

متن کامل

Differential response of peripheral arterial compliance-related indices to a vasoconstrictive stimulus.

Peripheral arterial elastic properties are greatly affected by cardiovascular as well as other pathologies, and their assessment can provide useful diagnostic indicators. The photoplethysmographic technique can provide finger blood volume and pressure waveforms non-invasively, which can then be processed statically or beat-to-beat to characterize parameters of the vessel wall mechanics. We empl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physiological research

دوره 63 Suppl 4  شماره 

صفحات  -

تاریخ انتشار 2014