Cortical bone trajectory for lumbar pedicle screws.

نویسندگان

  • B G Santoni
  • R A Hynes
  • K C McGilvray
  • G Rodriguez-Canessa
  • A S Lyons
  • M A W Henson
  • W J Womack
  • C M Puttlitz
چکیده

BACKGROUND CONTEXT Achieving solid implant fixation to osteoporotic bone presents a clinical challenge. New techniques and devices are being designed to increase screw-bone purchase of pedicle screws in the lumbar spine via a novel cortical bone trajectory that may improve holding screw strength and minimize loosening. Preliminary clinical evidence suggests that this new trajectory provides screw interference that is equivalent to the more traditionally directed trajectory for lumbar pedicle screws. However, a biomechanical study has not been performed to substantiate the early clinical results. PURPOSE Evaluate the mechanical competence of lumbar pedicle screws using a more medial-to-lateral path (ie, "cortical bone trajectory") than the traditionally used path. STUDY DESIGN Human cadaveric biomechanical study. METHODS Each vertebral level (L1-L5) was dual-energy X-ray absorptiometry (DXA) scanned and had two pedicle screws inserted. On one side, the traditional medially directed trajectory was drilled and tapped. On the contralateral side, the newly proposed cortical bone trajectory was drilled and tapped. After qCT scanning, screws were inserted into their respective trajectories and pullout and toggle testing ensued. In uniaxial pullout, the pedicle screw was withdrawn vertically from the constrained bone until failure occurred. The contralateral side was tested in the same manner. In screw toggle testing, the vertebral body was rigidly constrained and a longitudinal rod was attached to each screw head. The rod was grasped using a hydraulic grip and a quasi-static, upward displacement was implemented until construct failure. The contralateral pedicle screw was tested in the same manner. Yield pullout (N) and stiffness (N/mm) as well as failure moment (N-m) were compared and bone mineral content and bone density data were correlated with the yield pullout force. RESULTS New cortical trajectory screws demonstrated a 30% increase in uniaxial yield pullout load relative to the traditional pedicle screws (p=0.080), although mixed loading demonstrated equivalency between the two trajectories. No significant difference in construct stiffness was noted between the two screw trajectories in either biomechanical test or were differences in failure moments (p=0.354). Pedicle screw fixation did not appear to depend on bone quality (DXA) yet positive correlations were demonstrated between trajectory and bone density scans (qCT) and pullout force for both pedicle screws. CONCLUSIONS The current study demonstrated that the new cortical trajectory and screw design have equivalent pullout and toggle characteristics compared with the traditional trajectory pedicle screw, thus confirming preliminary clinical evidence. The 30% increase in failure load of the cortical trajectory screw in uniaxial pullout and its juxtaposition to higher quality bone justify its use in patients with poor trabecular bone quality.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Cortical Bone Trajectory: An Alternative to Traditional Pedicle Screw Fixation - A Review

The cortical based trajectory for pedicle screw fixation of the lumbar spine is not a novel as it once was. This is a review of the background, indications, advantages, disadvantages of cortical based trajectory pedicle screw fixation with an emphasis on biomechanical evidence and recent clinical studies which only now are just coming to light.

متن کامل

Should we use cortical bone screws for cortical bone trajectory?

OBJECT In 2009, Santoni et al. reported cortical bone trajectory (CBT) as a method of inserting pedicle screws to obtain more solid fixation, and proposed the use of cortical trajectory screws with a more closely placed thread (cortical screws) for CBT. Since the entry trajectory in CBT differs from that in the traditional trajectory, it is unclear whether the increased strength derives from th...

متن کامل

Short-Term Results of Transforaminal Lumbar Interbody Fusion Using Pedicle Screw with Cortical Bone Trajectory Compared with Conventional Trajectory

STUDY DESIGN Case-control study. PURPOSE To evaluate clinical and radiological results of transforaminal lumbar interbody fusion (TLIF) performed with cortical bone trajectory (CBT) pedicle screw insertion with those of TLIF using 'conventional' or percutaneous pedicle screw insertion. OVERVIEW OF LITERATURE CBT is a new trajectory for pedicle screw insertion in the lumbar spine; clinical a...

متن کامل

Fatigue Performance of Cortical Bone Trajectory Screw Compared With Standard Trajectory Pedicle Screw.

STUDY DESIGN Cadaveric biomechanical study. OBJECTIVE To determine fatigue behavior of cortical bone trajectory (CBT) pedicle screws. SUMMARY OF BACKGROUND DATA Cortical bone trajectory screws have been becoming popular in spine surgery; however, the long-term fatigue behavior of the new CBT screws remains understudied and limitations not well defined. METHODS Twelve vertebrae from six ca...

متن کامل

The Cortical Bone Trajectory for Pedicle Screw Insertion.

P edicle screw fixation for spinal stabilization is now commonplace in spine surgery. Traditionally, pedicle screws are placed through a trajectory in which screw insertion utilizes a transpedicular path through the axis of the pedicle, either paralleling the end plate, as in the straightforward trajectory, or following the anatomic axis of the pedicle with an approximately 22° cephalocaudal tr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • The spine journal : official journal of the North American Spine Society

دوره 9 5  شماره 

صفحات  -

تاریخ انتشار 2009