Comparison and verification of the reconstruction method of the catheters for interstitial brachytherapy
نویسندگان
چکیده
PURPOSE 1. Comparison and verification of accuracy of the implant reconstruction method based on images from IBU and CT. 2. Estimation of influence of the implant reconstruction method on dose disposition in selected reference points. MATERIAL AND METHODS Paraffin-wax phantom with three catheters, central marker and control point were prepared. IBU unit were used for obtaining two series of images for reconstruction. The Earth magnetic field correction algorithm was used to correct S-shape distortions of the images. CT images (1 mm slice) were prepared. In the treatment planning system positions of 15 catheter points (MP, measure points), control point (CP) and central marker (CM) were reconstructed for each series of images. Distances between 15 catheter points and control point, and between catheter points and central marker were calculated. RESULTS There were no statistically significant differences observed for IBU and CT based reconstructions for all orientations of the phantom (p > 0.05, U-Mann Whitney Test). There were no statistically significant differences observed between reconstruction based on IBU images with and without Earth magnetic field correction algorithm for phantom located perpendicular to the IBU table (p > 0.05, Wilcoxon Test). Statistically significant differences were observed only for images set with long axis of the phantom located parallel to the table (p < 0.05, Wilcoxon Test). There were no statistically significant differences observed for values doses in reference points for reconstruction based on IBU images and CT for all orientations of the phantom. CONCLUSIONS 1. Obtained results showed that IBU (radiographs based) reconstruction of the catheter placement is the reliable and accurate method for interstitial implants when reconstruction based on CT "catheter tracking" is not possible or not necessary. 2. The Earth magnetic field correction algorithm should be always use to correct S-shape distortions; reconstruction will be more accurate in particular orientations of image intensifier of the imaging unit.
منابع مشابه
Verification of delivered dose to the Lips carcinoma tumors with HDR brachytherapy sources: 192Ir and 60CO in an exclusive plexiglass Phantom.
Introduction: Brachytherapy, especially using manually after loaded Iridium-192 and Cobalt-60, can be applied as a sole treatment, as a treatment complementary to surgery, and as a local boost in combination with EBRT. The use of HDR brachytherapy catheters incorporated in removable dental molds allows repeated, highly reproducible, fractionated outpatient brachytherapy of supe...
متن کاملDeveloping a Verification and Training Phantom for Gynecological Brachytherapy System
Introduction Dosimetric accuracy is a major issue in the quality assurance (QA) program for treatment planning systems (TPS). An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT) of gynecological (Gyn) cancer it is usual to insert a combination of tandem and ovoid applicators with a complicat...
متن کاملA Comparison of Skin Dose Delivered with MammoSite and Multicatheter Breast Brachytherapy
Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients treated with breast brachytherapy.Objective: To investigate the percentage of the dose received by critical organ (skin), thermoluminescence detec...
متن کاملHistorical review of interstitial prostate brachytherapy
In the recent years, interstitial brachytherapy implantation has become the treatment of choice for early stage prostate cancer patients. Treatment of prostate cancer with radiation is traced back to 1909. Originally this treatment modality was very crude and could not gain much popularity till 1982. Advancements in radioactive source designs, introduction of new low energy radioactive sources,...
متن کاملComparison and Evaluation of the Effects of Rib and Lung Inhomogeneities on Lung Dose in Breast Brachytherapy using a Treatment Planning System and the MCNPX Code
Introduction: This study investigates to what extent the computed dose received by lung tissue in a commercially available treatment planning system (TPS) for 192Ir high-dose-rate breast brachytherapy is accurate in view of tissue inhomogeneities and presence of ribs. Materials and Methods: A CT scan of the breast was used to construct a patient-equivalent phantom in the clinical treatment plan...
متن کامل