An enrichment method of molybdenum on a cellulose nitrate resin for the determination by electrothermal atomic absorption spectrometry coupled with the resin suspension injection.
نویسندگان
چکیده
Cellulose derivative resin (CDR) suspensions containing resin particles of cellulose nitrate (CDR(CN)), cellulose acetate (CDR(CA)), or cellulose triacetate (CDR(CTA)) were prepared as the sorbent for resin suspension injection (RSI) electrothermal atomic absorption spectrometry (ETAAS), in which fine resin particles holding a desired trace element were directly injected into the graphite tube as the suspension. To compare the sorption ability, the distribution ratios of the Mo(VI)-phenylfluorone complex were measured between the aqueous phase and the sorbents, including the CDRs mentioned above and the finely divided anion exchange resin (AR). The results showed that the sorption ability decreases in the following order: CDR(CN) > or = AR > CDR(CA) > or = CDR(CTA). It was concluded that CDR(CN) was able to extract more than 98% of Mo(VI), and was suitable for RSI-ETAAS as well as AR. CDR(CN) was used for the determination of Mo in NIES certified reference materials, No. 10 Rice flour-unpolished; the results showed fairly good agreements between the analytical values and the certified values.
منابع مشابه
Determination of tin by resin-suspension electrothermal atomic absorption spectrometry after enrichment as the complex with ammonium pyrrolidinedithiocarbamate.
A resin-phase extraction method has been optimized for the trace determination of tin(II) by ETAAS. Tin(II) was extracted on a finely divided anion exchange resin as the complex with ammonium pyrrolidinedithiocarbamate (APDC). The resin was collected on a membrane filter and then dispersed in 1.00 ml of 1 mol l(-1) nitric acid containing 100 microg of Pd(II) and 60 microg of Ni(II). The resulti...
متن کاملDetermination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop
The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...
متن کاملSimultaneous Determination of Sub jig g-1 Levels of Impurities in High Purity Iron by Inductively Coupled Plasma-Atomic Emission Spectrometry after Circulation of Eluant through Anion Exchange Resin Mini-Column
Boron, Mo, Nb, Sn, Ta, W and Zr were separated from an iron matrix using a horizontal mini-column of an anion exchange resin. The flow of solutions through the mini-column was controlled by a peristaltic pump. The elements adsorbed on the resin were simultaneously eluted by the circulation of an eluant and determined by inductively coupled plasma-atomic emission spectrometry. Quantitative recov...
متن کاملDetermination of V(IV) and V(V) by electrothermal atomic absorption spectrometry following selective solid-phase extraction and the study on the change in the oxidation state of vanadium species in seawater during the sample storage.
The changes in the oxidation state of vanadium in artificial and natural seawater samples were studied by electrothermal atomic absorption spectrometry (ETAAS) with a direct injection of a resin suspension. V(IV) and V(V) were extracted as the complex with Chromazurol B and with N-cinnamoyl-N-2,3-xylylhydroxylamine, respectively, using a suspension of an anion-exchange resin and determined by E...
متن کاملElimination of Chemical and Spectral Interferences in Measurement of Trace Elements in Urine and Blood by Combined Electrodeposition-Electrothermal Atomic Absorption Spectrometry
A combined electrodeposition-ETAAS technique has been applied to the analysis of Pb, Cd, Co, Ni, Cr and Mn in biological samples in order to overcome interferences and to minimize sample pretreatment. It requires minimal sample preparation with the electrolysis process aiding partial decomposition of the organic matrix, adequate for the release and deposition of trace elements. In an initia...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- Analytical sciences : the international journal of the Japan Society for Analytical Chemistry
دوره 20 7 شماره
صفحات -
تاریخ انتشار 2004