Is there an advantage to delivering breast boost in the lateral decubitus position?
نویسندگان
چکیده
BACKGROUND The purpose of this study was to compare the change in depth of target volume and dosimetric parameters between the supine and lateral decubitus positions for breast boost treatment with electron beam therapy. METHODS We analyzed 45 patients who were treated, between 2009-2010, with whole breast radiation (WBRT) followed by a tumor bed boost in the lateral decubitius position. Tumor bed volume, distance from skin to the maximal depth of the tumor bed, D90 (dose covering 90% of the tumor bed volume), maximal dose, electron energy and doses to heart and lungs were compared. Additional variables of body mass index (BMI) and tumor bed location were also analyzed to see if there was a benefit limited to any subgroup. RESULTS Median BMI for the 45 patients treated was 30.6 (20.6-42.4). When comparing the supine scan to the lateral decubitus scan, there was no significant difference in the tumor bed volume (p = 0.116). There was a significant difference between depth to the tumor bed in the supine scan and lateral decubitus scan (p < 0.001). The mean maximum doses and D90 between the two scans were 110.7 (100.0-133.0)% vs 106.1 (95.1-116.9)% (p < 0.05) and 93.9 (81.3-01.0-101.0)% vs. 98.2 (89.1-108.0)% (p = 0.004) respectively. There was no difference in dose delivered to the lungs or heart between the two scans (p = 0.848 and p = 0.992 respectively). On subset analysis, there was a difference in depth to tumor that was seen across all BMI classes, including normal (p ≤ 0.001, overweight (p ≤ 0.001) and obese (p ≤ 0.001). The majority of patients had a tumor in the upper outer quadrant (77.8%) and on subset analysis, there was a significant difference in tumor bed volume (p < 0.01), depth to tumor (p < 0.01), tumor bed coverage [D90] (p < 0.05), maximum dose (p < 0.05) and energy (p < 0.001) for this location. CONCLUSIONS Delivering a tumor bed boost in the lateral decubitus position reduces the distance to the tumor bed allowing for a lower energy treatment to be used to treat breast cancer. It improves coverage and decreases maximal dose to the target volume, all of which would help reduce skin morbidities and should be considered for patients with upper outer quadrant disease, irrespective of BMI status.
منابع مشابه
THE EFFECT OF CHANGE IN POSITION ON INTRATRACHEAL CUFF PRESSURE IN PATIENTS UNDERGOING SURGERY WITH GENERAL ANESTHESIA: A PROSPECTIVE ANALYTICAL STUDY
Background & Aims: Tracheal intubation with a cuffed tube for the administration of general anesthesia is routine. The cuff of the endotracheal tube is inflated with air to achieve an adequate seal to prevent aspiration and leakage of air and anesthetic gases. Whereas over-inflation can decrease the mucosal perfusion, leading to pressure necrosis and nerve palsies. This study aimed to evaluate ...
متن کاملComparison of success rates in performing lumbar puncture and reduction of its anxiety and pain between standard sitting and lateral decubitus positions in 1 to 5-year-old children
Background: Lumbar puncture (LP) is a worth procedure in diagnosis of oncological diseases and intrathecal administration of antineoplastic drugs. The effort should be to minimize pain of LP in children with cancers. This clinical trial was done to compare success rates in performing LP and reducing anxiety and pain of LP in sitting and lateral decubitus positions in 1 to 5-year-old children. ...
متن کاملLateral Decubitus Positioning Stereotactic Vacuum-Assisted Breast Biopsy with True Lateral Mammography
Stereotactic vacuum-assisted breast biopsy (VAB) has been used to evaluate microcalcifications or non-palpable breast lesions on mammography. Although stereotactic VAB is usually performed in a prone or upright position, an expensive prone table is necessary and vasovagal reactions often occur during the procedure. For these reasons, the lateral decubitus position can be applied for stereotacti...
متن کاملStereotactic vacuum-assisted breast biopsy under lateral decubitus position.
PURPOSE Stereotactic vacuum-assisted breast biopsy (VAB) has been established as a standard method for histological diagnosis of microcalcification or nonpalpable breast lesions on mammography. Generally, the procedure has been done under the prone position or upright sitting position. We herein attempt to evaluate clinical utility of Stereotactic VAB under lateral decubitus position. METHODS...
متن کاملهرنیاسیون قلب پس از رادیکال پنومونکتومی: گزارش موردی و بررسی متون
Background: Cardiac herniation is a fatal post pneumonectomy complication. We report the signs, clinical findings, diagnosis and management of a patient with post pneumonectomy cardiac herniation.Case report: A 34-year-old man with lung cancer underwent left pneumonectomy with partial pericardiectomy in the right lateral decubitus position. At the end of the surgery, cardiovascular collapse, se...
متن کامل