Near Visual Performance Results of the Accommodating Intraocular Lens (Tetraflex)® in Comparison to Monofocal Foldable Intraocular Lens

نویسندگان

  • Firoozeh Rahimi
  • Elham Ghahari
  • Mohammad Reza Fallah
  • Mohammad Taher Rajabi
چکیده

Purpose: To evaluate the near visual performance of an accommodative intraocular lens (IOL); Tetraflex, in comparison to a standard monofocal foldable IOL in cataract surgery. Setting: Eye Research Center, Farabi Eye Hospital, Department of Ophthalmology, Tehran University of Medical Sciences, Iran. Methods: Forty six eyes of 23 patients with cataract underwent phacoemulsification and accommodative IOL (Tetraflex) implantation bilaterally (case group). The same number of agematched control group were implanted a foldable monofocal IOL bilaterally (control group). Outcome measures were uncorrected distance visual acuity (UCDVA), uncorrected near visual acuity (UCNVA), manifest refraction, best corrected distance visual acuity (BCDVA), distance corrected near visual acuity (DCNVA), and the amplitude of accommodation up to 6 months after surgery. Results: The final BCDVA was better than /25 in all eyes. Mean±standard deviation (SD) DCNVA in the accommodative IOL group (0.69±0.25) was significantly higher than monofocal foldable IOL (0.18±0.09) six months following surgery (P<0.001). Eighty nine percent (41 eyes of 46) of the accommodative IOL group achieved DCNVA of /40 or better 6 months after surgery. At 1 month after surgery, mean±SD accommodation in the case group was 3.86±1.11 D compared to 0.27±0.18 D in the control group (P<0.001). Six months after operation, 95.7% of the patients in the case group had 2.5 D or more accommodation compared to a mean of 0.48 D in the control group. Conclusion: The accommodative IOL provides both enhanced near vision and good distance vision 6 month after surgery. It seems that patient's dependence to near add will be decreased and they can have a good range of clear vision.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

US FDA clinical trial of the Tetraflex potentially accommodating IOL: comparison to concurrent age-matched monofocal controls.

PURPOSE To assess the efficacy of the Tetraflex (Lenstec Inc) intraocular lens (IOL) to provide enhanced near reading ability and spectacle independence relative to a monofocal control IOL in bilaterally implanted eyes tested binocularly. METHODS A prospective, age-matched, non-randomized US Food and Drug Administration clinical trial of 255 Tetraflex and 101 monofocal IOL control patients wa...

متن کامل

Potential of the 1 CU accommodative intraocular lens.

AIM To assess the accommodative power of a new foldable monofocal intraocular lens. METHOD A prospective randomised non-masked clinical interventional study. The study included 40 patients attending the hospital for cataract surgery and who were randomly distributed into a study group receiving a new foldable monofocal intraocular lens with flexible haptics, and a control group receiving a st...

متن کامل

Visual and Refractive Outcomes of Phacoemulsification with Implantation of Accommodating versus Standard Monofocal Intraocular Lenses.

PURPOSE To compare distant and near visual function after cataract surgery with implantation of Crystalens HD or Tek-Clear as accommodating intraocular lenses (IOLs), versus SA60AT as a standard IOL. METHODS The study included 62 eyes of 58 patients divided into three groups using three different IOLs: Crystalens HD (Bausch and Lomb, NY, USA), Tek-Clear (Tekia, CA, USA) and SA60AT (Alcon, TX,...

متن کامل

Functional reading acuity and performance: Comparison of 2 accommodating intraocular lenses.

PURPOSE To compare functional reading acuity and speed with 2 models of accommodating intraocular lenses (IOLs). SETTING Four of 12 investigative sites in a U.S. Food and Drug Administration (FDA) clinical study. METHODS In this observational study, which was part of an ongoing FDA clinical trial, the MNRead functional reading test was used to compare the reading performance of patients wit...

متن کامل

Comparison of Visual Performance of Multifocal Intraocular Lenses with Same Material Monofocal Intraocular Lenses

PURPOSE To compare the visual performance of multifocal intraocular lenses (IOLs) and monofocal IOLs made of the same material. METHODS The subjects included patients implanted with either Tecnis® monofocal IOLs (ZA9003 or ZCB00) or Tecnis® multifocal IOLs (ZMA00 or ZMB00) bilaterally. We conducted a retrospective study comparing the two types of IOLs. The multifocal group included 46 patient...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009