Comparison of various vacuum mixing systems and bone cements as regards reliability, porosity and bending strength.

نویسندگان

  • Hans Mau
  • Katrin Schelling
  • Christian Heisel
  • Jian-Shang Wang
  • Steffen J Breusch
چکیده

BACKGROUND There are several vacuum mixing systems on the market which are arbitrarily used with various bone cements in clinical work. Hardly any studies have been done on the performance and handling of these systems in combination with different cement brands. MATERIAL AND METHODS We therefore tested 6 vacuum mixing systems (Palamix, Summit, Cemvac, Optivac, Vacumix, MixOR) in combination with 6 cement brands (Palacos R, Simplex P, CWM 1, CWM 2000, Palamed G, VersaBond) concerning their reliability, user-friendliness, porosity and bending strength. RESULTS Our study indicated that each system has weak points. The preparation of the mixed cement for gun injection can present problems. If cement collection under vacuum fails, porosity is increased. Manual collection without a vacuum carries the risk of intermixing air. For comfortable and effective retrograde cement application, cement guns should have a stable connection with the cartridge and a high piston stroke. There are marked differences between the systems as regards overall porosity when all tested cements are considered (range 2-18%), and between the cements when all tested systems are considered (range 2-17%). All test samples exceeded the required bending strength of 50 MPa, according to ISO 5833. Palaces specimens showed excessive plastic deformation in the bending test. INTERPRETATION There are better and worse mixing system/cement combinations for a given system and a given cement. Systems with cement collection under vacuum reduce porosity best.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of vacuum mixing and pre-heating the femoral component on the mechanical properties of the cement mantle.

We investigated the effect of pre-heating a femoral component on the porosity and strength of bone cement, with or without vacuum mixing used for total hip replacement. Cement mantles were moulded in a manner simulating clinical practice for cemented hip replacement. During polymerisation, the temperature was monitored. Specimens of cement extracted from the mantles underwent bending or fatigue...

متن کامل

The clinical significance of vacuum mixing bone cement.

This controlled study compared the strength and porosity of 48 polymethylmethacrylate cement-implant constructs prepared with open bowl versus vacuum mix technique. Forty-eight blast finished stainless steel rods of 13 mm diameter were implanted with centralizers into 17-mm inner diameter tubes that had been retrograde filled with polymethylmethacrylate cement. The eight cement preparations use...

متن کامل

Acrylic antibiotic-loaded bone cement: a basic study

  Abstract   Objective: The aim of this study was to evaluate the efficacy of antibiotic-loaded bone   cement in controlling local infection and in regard to its physical characteristics, elastic   modulus, and tensile strength in-vitro.   Methods: Acrylic bone cement, based on polymethylmethacrylate (PMMA) was   mixed with the powder form of three antibiotics, i.e., gentamicin, tobramycin, and...

متن کامل

Compression Strength and Porosity of Single-Antibiotic Cement Vacuum-Mixed with Additional Vancomycin

Introduction Frequently in joint replacement surgery, antibiotics are combined with acrylic cement to provide high local drug concentrations for prevention and treatment of infection. In 2003, the FDA approved the sale of single-antibiotic cement for use in septic arthroplasty cases. Such cements can now be purchased from various manufacturers. A major disadvantage of adding antibiotics to bone...

متن کامل

Effects of porosity on the fatigue performance of polymethyl methacrylate bone cement: an analytical investigation.

Porosity has been shown to affect the fatigue life of bone cements, but, although vacuum mixing is widely used to reduce porosity in the clinical setting, results have been mixed and the effects of porosity are not well understood. The aim of this study was to investigate the effects of porosity using stress analysis and fracture mechanics techniques. The stress concentrations arising at voids ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Acta orthopaedica Scandinavica

دوره 75 2  شماره 

صفحات  -

تاریخ انتشار 2004