Time-of-flight MR angiography of carotid artery stenosis: does a flow void represent severe stenosis?
نویسندگان
چکیده
BACKGROUND AND PURPOSE Time-of-flight (TOF) magnetic resonance angiography (MRA) is commonly used to visualize the carotid arteries; however, flow void artifacts can appear. Our purpose was to determine the frequency and diagnostic meaning of flow voids by using real patient data, as part of a larger study of MRA compared with the criterion standard, digital subtraction angiography (DSA). METHODS In 1997-2000, 390 consecutive patients with sonographic findings suggestive of carotid artery stenosis were included in this study. All patients subsequently underwent three-dimensional (3D) TOF MRA and conventional DSA. The frequency of flow void artifacts on 3D TOF MRA images were compared with stenosis measurements on DSA images. RESULTS We recorded 107 flow voids (16%) during 3D TOF MRA of 662 carotid arteries. DSA images were available for comparison in 102 cases. The median percentage of stenosis in this subgroup of flow voids on MRA images was 80%, compared with measurements on DSA images according to the North American Symptomatic Carotid Endarterectomy Trial (NASCET) criteria. Stenoses ranged from 36% to 100% (occlusion). Three flow voids (2.9%) were in the 0-49% range; 11 (10.8%), in the 50-69% range; and 86 (84.3%), in the 70-99% range. Two flow voids (2.0%) represented occlusions. The positive predictive value of a flow void artifact for the presence of severe (70-99%) stenosis was 84.3% (95% CI: 77.3%, 91.4%). CONCLUSION Flow void artifacts represented severe stenosis in most of the arteries. According to our data, the assumption that flow voids on 3D TOF MRA images represent severe stenosis is justified.
منابع مشابه
Effect of carotid endarterectomy on primary collateral blood flow in patients with severe carotid artery lesions.
BACKGROUND AND PURPOSE In patients with severe obstruction of the internal carotid artery (ICA), it is recognized that the preoperative failure to visualize collaterals of the circle of Willis increases the risk of hemispheric ischemia before, during, and after carotid endarterectomy (CEA). The purpose of the present study was to assess the effect of CEA on the anatomy and function of the circl...
متن کامل3DFT MR angiography of carotid and basilar arteries.
Three-dimensional Fourier transform (3DFT) time-of-flight and two-dimensional Fourier transform (2DFT) projection phase-contrast MR angiography was performed in eight healthy volunteers and in 14 patients with known carotid artery or basilar artery occlusion, stenosis, or dissection. Comparative angiography was available in 13 cases (although in some cases the studies were separated by a number...
متن کاملMR angiographic and sonographic indications for endarterectomy.
PURPOSE Our objective was to determine whether appropriate criteria could be developed for performing an endarterectomy on the basis of sonographic and MR angiographic findings. METHODS Fifty patients were examined prospectively with sonography, MR angiography, and conventional angiography. All three imaging studies were performed within 2 weeks of one another, and conventional angiography se...
متن کاملCarotid Artery Stenosis: Comparison of 3D Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography at 3T
Purpose. The aim of this study was to assess the correlation of 3D time-of-flight MR angiography (TOF MRA) and contrast-enhanced MR angiography (CEMRA) for carotid artery stenosis evaluation at 3T. Material and Methods. Twenty-three patients (5 f, 18 m; mean age 61 y, age range 45-78 y) with internal carotid artery stenosis detected with ultrasonography were examined on a 3.0T MR system. The MR...
متن کاملRoutine MR imaging of the internal carotid artery siphone: angiographic correlation with cervical carotid lesions.
This study correlates the appearance of the cavernous segment of the carotid artery on MR images with the presence of significant stenosis or occlusion of the cervical carotid artery as seen on angiograms in 100 patients who had brain MR imaging and arteriography within a 1-week period. Four patients demonstrated isointense signal within the carotid artery's cavernous segment; two of these find...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید
ثبت ناماگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید
ورودعنوان ژورنال:
- AJNR. American journal of neuroradiology
دوره 23 10 شماره
صفحات -
تاریخ انتشار 2002