A stature-specific concept for uncemented, primary total hip arthroplasty
نویسندگان
چکیده
BACKGROUND AND PURPOSE Variations in hip anatomy limit the femoral canal fit of standard uncemented hip stems. In addition, there are still issues with leg length discrepancy and offset reconstruction, potentially resulting in impingement, dislocation, and wear. Modular stems with different shapes for femoral canal fit and multiple neck options may improve the outcome and reduce complications. PATIENTS AND METHODS 173 patients (190 hips) received an uncemented THA with 1 of 2 different stem shapes for canal fit and a modular neck for stature-specific hip reconstruction. Median follow-up time was 9 (7-13) years. During the follow-up period, 20 patients died (22 hips) and 12 patients (13 hips) were lost to follow-up. 155 hips were available for evaluation, including clinical and radiological outcome. RESULTS 1 stem was revised for a periprosthetic fracture following trauma; 10 cups and 2 modular necks were revised (1 for breakage and 1 during cup revision). At 10 years, stem survival was 100%, modular neck survival was 99% (CI: 95-100), and cup survival was 94% (CI: 87-97). No leg length discrepancies were measured in 96% of cases. Offset with anatomic lateralization was achieved in 98%. Median Harris hip score was 94 (47-100) and median Merle d'Aubigné score was 16 (10-18). Relevant radiolucent lines and osteolysis were not found. INTERPRETATION The uncemented modular neck, dual-stem system used in this series allows accurate reconstruction of the joint by adapting the implant to the needs of the patient. This may improve the outcome of primary THA, which is supported by the results of this medium-term follow-up evaluation.
منابع مشابه
The relative cost of cemented and uncemented total hip arthroplasties.
The use of uncemented femoral stems in primary total hip arthroplasty (THA) has been slow to develop in the UK because of the lack of encouraging published long-term follow-up data, the continued success of the cemented primary THA, and the perceived excessive relative cost of the uncemented THA. In this article, we argue that the total costs of 3 "proven" uncemented stems are comparable with c...
متن کاملAssistant Attending Orthopaedic Surgeon, and Surgeon-in-Chief and Korein-Wilson Professor of Orthopaedic Surgery, Hospital for Special Surgery
Uncemented modular cups are the preferred implants for primary total hip arthroplasty (PTHA). Cemented all-polyethylene cups are still popular in Europe; however, the high prevalence of radiographic loosening observed after the first decade of implantation in young patients and the concept of ‘cement disease’ collaborated to generate skepticism about the use of cement for acetabular fixation. S...
متن کاملHumeral-sided Radiographic Changes Following Reverse Total Shoulder Arthroplasty
Background: We sought to characterize humeral-sided radiographic changes at a minimum of 2 years after reverseshoulder arthroplasty (RSA) to determine their association with specific implantation techniques.Methods: The immediate and most recent postoperative anteroposterior radiographs of 120 shoulders with primary RSAand a minimum of 2-years of radiographic follow-up were an...
متن کاملIncreased risk for early periprosthetic fractures after uncemented total hip replacement.
INTRODUCTION The purpose of this study was to describe a new type of proximal periprosthetic fracture occurring within the first six weeks after total hip arthroplasty and to analyse possible causes of a rising incidence. MATERIAL AND METHODS Patient files and radiographs from 2,408 uncemented hip replacements were analysed and patients with a periprosthetic split fracture reaching from the c...
متن کاملA cemented cup with acetabular impaction bone grafting is more cost-effective than an uncemented cup in patients under 50 years.
PURPOSE Acetabular deficiencies in young patients can be restored in several ways during total hip arthroplasty. Currently, cementless cups are most frequently used. Impaction bone grafting of acetabular defects is a more biological approach, but is it cost-effective in young patients on the long term? METHODS We designed a decision model for a cost-utility analysis of a cemented cup with ace...
متن کامل