Evaluation of a Laser Doppler System for Myocardial Perfusion Monitoring

نویسنده

  • Carina Fors
چکیده

Coronary artery bypass graft (CABG) surgery is a common treatment for patients with coronary artery disease. A potential complication of CABG is myocardial ischemia or infarction. In this thesis, a method — based on laser Doppler flowmetry (LDF) — for detection of intraand postoperative ischemia by myocardial perfusion monitoring is evaluated. LDF is sensitive to motion artifacts. In previous studies, a method for reduction of motion artifacts when measuring on the beating heart has been developed. By using the ECG as a reference, the perfusion signal is measured in intervals during the cardiac cycle where the cardiac motion is at a minimum, thus minimizing the artifacts in the perfusion signal. The aim of this thesis was to investigate the possibilities to use the ECGtriggered laser Doppler system for continuous monitoring of myocardial perfusion in humans during and after CABG surgery. Two studies were performed. In the first study, changes in myocardial perfusion during CABG surgery were investigated (n = 13), while the second study focused on postoperative measurements (n = 13). In addition, an ECG-triggering method was implemented and evaluated. It was found that the large variations in myocardial perfusion during CABG surgery could be monitored with the ECG-triggered laser Doppler system. Furthermore, a perfusion signal of good quality could be registered postoperatively from the closed chest in ten out of thirteen patients. In eight out of ten patients, a proper signal was obtained also the following morning, i.e., about 20 hours after probe insertion. The results show that respiration and blood pressure can have an influence on the perfusion signal. In conclusion, the results indicate that the method is able to detect fluctuations in myocardial perfusion under favourable circumstances. However, high heart rate, abnormal cardiac motion, improper probe attachment and limitations in the ECG-triggering method may result in variations in the perfusion signal that are not related to tissue perfusion.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Tc-99m-MIBI in evaluation of myocardial perfusion [Persian]

Tc-99m-MIBI is an isonrtrile derivative used for evaluation of myocardial perfusion in recent years. In this preliminary report, 7 patients with coronary artery disease are evaluated with Tc-99m-MlBl stress planar and sped studies. Good correlation with coronary angiography is observed in these cases. In view of inherent technical problems present with thallium 201, Tc-99m-MIBi is a good ...

متن کامل

Evaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy

Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...

متن کامل

Experimental and Clinical Evaluation of Capsular and Parenchymal Total Liver Perfusion

Liver blood flow measurements obtained from both the liver surface and deep within the parenchyma, were correlated in an effort to assess the usefulness of laser-Doppler flowmetry for non-invasive monitoring of total liver blood flow, the probe being positioned on either the surface or within the liver parenchyma. In 23 Wistar rats and 10 biliary surgery patients, anaesthetized prior to gallbla...

متن کامل

Myocardial perfusion scan accuracy in detection of coronary artery disease - Comparison with exercise stress test [Persian]

Introduction: In patients with coronary artery disease (CAD) noninvasive evaluation for detection of ischemia is important to avoid invasive interventions like angiography. Exercise stress test is conventionally the first study used in evaluation of CAD. Considering the noninvasive nature of the myocardial perfusion scan, we decided to compare its accuracy with stress test. Methods: Patie...

متن کامل

Myocardial perfusion SPECT: Perfusion quantification

Different software tools for quantification of myocardial perfusion SPECT (MPS) studies are routinely used. Several perfusion parameters can be computed automatically.  Interpretation of the MPS should start with visual inspection of the rotating planar images, visual analysis of reconstructed SPECT slices and then quantitative analysis to confirm the visual impression. Quantification should be...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007