Quantifying the local influence at a tall tower site in nocturnal conditions
نویسندگان
چکیده
The influence of the local terrestrial environment on nocturnal atmospheric CO2 measurements at a 329-m television transmitter tower (and a component of a CO2 monitoring network) was estimated with a tracer release experiment and a subsequent simulation of the releases. This was done to characterize the vertical transport of emissions from the surface to the uppermost tower level and how it is affected by atmospheric stability. The tracer release experiment was conducted over two nights in May of 2009 near the Department of Energy’s Savannah River Site (SRS) in South Carolina. Tracer was released on two contrasting nights—slightly stable and moderately stable—from several upwind surface locations. Measurements at the 329-m level on both nights indicate that tracer was able to mix vertically within a relatively short (∼24 km) distance, implying that nocturnal stable conditions do not necessarily prevent vertical dispersion in the boundary layer and that CO2 measurements at the tower are at least partly influenced by nearby emissions. A simulation of the tracer release is used to calculate the tower footprint on the two nights to estimate the degree to which the local domain affects the tower readings. The effect of the nocturnal boundary layer on the area sampled by the tower can be seen clearly, as the footprints were affected by changes in stability. The contribution of local sources to the measurements at the tower was minimal, however, suggesting that nocturnal concentrations at upper levels are contributed mostly by regional sources.
منابع مشابه
The Effect of Soil Type on Seismic Response of Tall Telecommunication Towers with Random Vibration Analysis
Random vibration analysis of tall structures faces multiple problems due to the large number of elements and high degrees of freedom; that is why this type of analysis is mostly used in simple structures and low degrees of freedom. In the past two decades, changes have been occurred in this type of analysis to be used in complex structures and the large number of elements. Pseudo-Excitation Met...
متن کاملAtmospheric stability effects on potential radiological releases at a nuclear research facility in Romania: Characterising the atmospheric mixing state.
A radon-based nocturnal stability classification scheme is developed for a flat inland site near Bucharest, Romania, characterised by significant local surface roughness heterogeneity, and compared with traditional meteorologically-based techniques. Eight months of hourly meteorological and atmospheric radon observations from a 60 m tower at the IFIN-HH nuclear research facility are analysed. H...
متن کاملEstimating daytime CO2 fluxes over a mixed forest from tall tower mixing ratio measurements
[1] Difficulties in estimating terrestrial ecosystem CO2 fluxes on regional scales have significantly limited our understanding of the global carbon cycle. This paper presents an effort to estimate daytime CO2 fluxes over a forested region on the scale of 50 km in northern Wisconsin, USA, using the tall-tower-based mixed layer (ML) budget method. Budget calculations were conducted for 2 years u...
متن کاملCarbon dioxide column abundances at the Wisconsin Tall Tower site
[1] We have developed an automated observatory for measuring atmospheric column abundances of CO2 and O2 using near-infrared spectra of the Sun obtained with a high spectral resolution Fourier Transform Spectrometer (FTS). This is the first dedicated laboratory in a new network of ground-based observatories named the Total Carbon Column Observing Network. This network will be used for carbon cy...
متن کاملStudy of Degradation of Dry Cooling Tower Performance under Wind Conditions and Method for Tower Efficiency Enhancement (RESEARCH NOTE)
Wind affects adversely the cooling tower thermal performance. A field investigation was carried out to study the thermal performance of Heller cooling towers under wind conditions, involving measurement of wind velocity and its direction around the cooling tower, and obtaining water flow rates and temperatures at the cooling tower inlet and outlet. Results show that air suction at the tower top...
متن کامل