A biomechanical evaluation of anterior and posterior tibialis tendons as suitable single-loop anterior cruciate ligament grafts.

نویسندگان

  • Tammy L Haut Donahue
  • Stephen M Howell
  • Maury L Hull
  • Colin Gregersen
چکیده

PURPOSE Because allograft tendons used to replace a torn anterior cruciate ligament are in short supply, it is useful to explore other possible graft sources. The purpose of this study was to determine whether a graft formed from a loop of either an anterior or posterior tibialis tendon has structural, material, and viscoelastic properties similar to those of a double-looped semitendinosus and gracilis (DLSTG) graft. TYPE OF STUDY Completely randomized design. METHODS Four structural and 3 material properties were determined for each type of graft (n = 10) by measuring the cross-sectional area, looping the tendon(s) over a post, gripping the free ends of the tendon(s) with a freeze clamp, and pulling the graft to failure by using a materials testing system. Two viscoelastic properties were determined for each type of graft (n = 10) by measuring the decrease in load under a constant displacement (i.e., stress relaxation test) and the increase in displacement under a constant load (i.e., creep test). RESULTS For grafts 95 mm in length, the ultimate load and ultimate displacement of a loop of anterior (4,122 N, 12.0 mm) and posterior tibialis (3,594 N, 12.5 mm) tendon were either similar to or significantly greater than those of the DLSTG graft (2,913 N, 8.4 mm) (P =.204 for the posterior tibialis ultimate load and P < or =.007 for the remaining quantities). The stiffness and cross-sectional area of the anterior (460 N/mm, 48.2 mm2) and posterior tibialis (379 N/mm, 41.9 mm2) grafts were similar to those of the DLSTG graft (418 N/mm, 44.4 mm2) (P > or =.283). The tensile modulus, stress at ultimate load, and strain at ultimate load of the anterior tibialis and posterior tibialis grafts were either similar to or significantly greater than those of the DLSTG graft. The decrease in load of the anterior tibialis and posterior tibialis grafts was either greater than or similar to that of the DLSTG graft for the relaxation test (P < or =.066). The increase in displacement of the anterior tibialis (0.3 mm) and posterior tibialis (0.4 mm) grafts was minimally but significantly greater than that of the DLSTG graft (0.2 mm) for the creep test (P < or =.004). CONCLUSIONS The structural, material, and viscoelastic properties of a single loop of anterior tibialis and posterior tibialis tendon are either better than or similar to those of a DLSTG graft. Consequently, single-loop grafts formed from tibialis tendons should function well as a replacement for a torn anterior cruciate ligament.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A biomechanical comparison of fan-folded, single-looped fascia lata with other graft tissues as a suitable substitute for anterior cruciate ligament reconstruction.

PURPOSE The purpose of this study was to evaluate the initial biomechanical properties of a fan-folded, single-loop construct of fan-folded fascia lata allograft in comparison to other graft tissues currently being used for anterior cruciate ligament (ACL) reconstruction. METHODS Eighteen fascia lata specimens were harvested from 11 donors and fan folded through a proprietary process. Bone-pa...

متن کامل

Principles for using hamstring tendons for anterior cruciate ligament reconstruction.

The use of autogenous hamstring tendon as a graft source for anterior cruciate ligament (ACL) reconstruction continues to gain in popularity. The low harvest morbidity and excellent biomechanical graft properties coupled with improved fixation of soft tissue grafts are all reasons for excellent clinical outcomes of ACL reconstruction using hamstring tendons. In addition, surgeon awareness of th...

متن کامل

Biomechanical Comparison Between Bashti Bone Plug Technique and Biodegradable Screw for Fixation of Grafts in Ligament surgery

  Background: Ligament reconstruction is a common procedure in orthopedic surgery. Although several popular techniques are currently in use, new methods are proposed for secure fixation of the tendon graft into the bone tunnel. Purposes: We sought to introduce our new technique of Bashti bone plug for fixation of soft tissue graft in anterior cruciate ligament (ACL) reconstruction and to compar...

متن کامل

Lengthening of a single-loop tibialis tendon graft construct after cyclic loading: a study using Roentgen stereophotogrammetric analysis.

Although single-loop tibialis tendon allografts have increased in popularity owing to their many advantages over patellar tendon and double-loop hamstring tendon autografts, some percentage of the patient population do not have clinically stable knees following anterior cruciate ligament reconstruction with single-loop tibialis tendon allografts. Therefore, it would be advantageous to determine...

متن کامل

Anterior Cruciate Ligament Reconstruction with Hamstring Tendons Has no Deleterious Effect on Hip Extension Strength

Background: Hamstring tendons are secondary hip extensors. Their harvest for graft in anterior cruciate ligament(ACL) reconstruction may create deleterious effect on hip extension strength. This is of particular importance in sportsthat need powerful hip extension force like climbing and sprinting. Due to scarcity of a comprehensive study in thisarea, we designed this prospect...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association

دوره 18 6  شماره 

صفحات  -

تاریخ انتشار 2002