Emission characteristics and vapour/particulate phase distributions of PCDD/F in a hazardous waste incinerator under transient conditions

نویسندگان

  • Min Li
  • Chao Wang
  • Kefa Cen
  • Mingjiang Ni
  • Xiaodong Li
چکیده

Polychlorinated dibenzo-p-dioxin and polychlorinated dibenzofuran (PCDD/F) emission characteristics and vapour/particulate phase partitions under three continued operation conditions, i.e. shut-down, start-up and after start-up, were investigated by sampling stack gas. The results indicated that the PCDD/F emission levels were 0.40-18.03 ng I-TEQ Nm-3, much higher than the annual monitoring level (0.016 ng I-TEQ Nm-3). Additionally, the PCDD/F emission levels in start-up were higher than the other two conditions. Furthermore, the PCDD/F congener profiles differed markedly between shut-down and start-up, and the chlorination degree of PCDD/F increased in shut-down and decreased evidently in start-up. Moreover, PCDD/F vapour/particulate phase distributions varied significantly under three transient conditions. The PCDD/F vapour phase proportion decreased as the shut-down process continued, then increased as the start-up process proceeded, finally more than 98% of the PCDD/F congeners were distributed in the vapour phase after start-up. The correlations between log(Cv/Cs ) versus [Formula: see text] of each PCDD/F congener in stack gas were disorganized in shut-down, and trend to a linear distribution after start-up. Besides, polychlorinated biphenyl emissions show behaviour similar to that of PCDD/F, and the lower chlorinated congeners have a stronger relationship with 2,3,7,8-PCDD/Fs, such as M1CB and D2CB.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Emissions of Polychlorinated Dibenzo-p-dioxins and Dibenzofurans from Various Stationary Sources

This work investigated the characteristics of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/F) in stack-flue gases from six stationary emission sources in five types of incinerators: industrial waste incinerator (IWI), small-scale municipal solid waste incinerator (MSWI), medical waste incinerator (MWI), cement kilns (CK), and crematories (CR). These characteristics were further inv...

متن کامل

Health survey on workers and residents near the municipal waste and industrial waste incinerators in Korea.

Hazardous substances, such as polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) also have been detected in Municipal Solid Waste (MSW) and industrial waste incinerators in Korea. In this study, we estimated the exposure status of these hazardous substances and their heath effects in workers and residents near the MSW incinerators and residents near the industri...

متن کامل

PCDD/F levels in the neighbourhood of a municipal solid waste incinerator after introduction of technical improvements in the facility.

In 1998 and 1999, the concentrations of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) were determined in soil and herbage samples collected in the vicinity of an old municipal solid waste incinerator (MSWI) (S. Adrià del Besòs, Barcelona, Spain). Just after the 1999 collection, an adaptation to the EU legislation on pollutant emissions from the stack was carried out in this faci...

متن کامل

Effects of gaseous NH(3) and SO(2) on the concentration profiles of PCDD/F in flyash under post-combustion zone conditions.

The influence of gaseous ammonia and sulphur dioxide on the formation of 2378-substituted PCDD/F on a reference flyash from a municipal waste incinerator has been investigated using a laboratory scale fixed-bed reactor. The reference flyash samples (BCR-490) was reacted under a simulated flue gas stream at temperatures of 225 and 375°C for 96h. The experiments were carried out in two series: fi...

متن کامل

Effects of heat recovery for district heating on waste incineration health impact: a simulation study in Northern Italy.

The construction of waste incinerators in populated areas always causes substantial public concern. Since the heat from waste combustion can be recovered to power district heating networks and allows for the switch-off of domestic boilers in urbanized areas, predictive models for health assessment should also take into account the potential benefits of abating an important source of diffuse emi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 5  شماره 

صفحات  -

تاریخ انتشار 2018